HCWB2 − Humidifier

 / Page 3

TYPICAL APPLICATIONS

HUMIDIFIER

HORIZONTAL UNIT

SUPPLY

AIR

RETURN

AIR

UP−FLOW UNIT

HUMIDIFIER

RETURN

AIR

SUPPLY

AIR

DOWN−FLOW UNIT

RETURN

AIR

SUPPLY

AIR

HUMIDIFIER

DIMENSIONS − INCHES (MM)

FRONT VIEW

LEFT SIDE VIEW

BACK VIEW

9-1/2 (241)

OPENING

10 (254)

12 (305)

1-1/2 (38)

2 (51)

A

SUMMER / WINTER

DAMPER CONTROL

6 (152) DIA.

BY−PASS DUCT

CONNECTION

B

OPENING

1

 AIR FLOW

NOTES:

By−pass duct air flow direction is dependent on application.

For up−flow/horizontal applications air flow is from the humidifer to return air duct.

For down−flow applications, air−flow is to the humidifier from the supply air duct.

1

 Left hand air inlet/outlet shown. For right−hand inlet/outlet, rotate humidifier cabinet 180º top for bottom and relocate solenoid valve

   and drain to alternate location on cabinet. See Installation Instructions for additional details.

DRAIN

SOLENOID

VALVE

 

Model No

A

B

Model No.

in.

mm

in.

mm

HCWB2−12
HCWBK2−12
HCWB2−12A
HCWBK2−12A

12−1/8

308

10

254

HCWB2−17
HCWB2−17A
HCWBK2−17A

15−5/8

397

13−1/2

343

Содержание HCWB2

Страница 1: ...own flow applications See Typical Applications Provides additional humidity to the home during the heating season to increase comfort level Humidifier saddle valve and humidistat universal humidifier control shipped in one package Approvals Units are ETL listed per ANSI UL 998 and CSA C22 2 No 104 01 Sequence of Operation Humidifier will only operate when indoor blower is operating When the level ...

Страница 2: ...e with stainless steel seat Drain 1 2 in drain fitting at bottom of cabinet 1 2 in ID plastic tubing must be field provided for models without Installation Kit Unused water from the evaporator pad is drained from the unit to help remove mineral deposits left from the evaporative process Equaflot Distribution Tray Deep reservoir and unique channel design provides even water distribution across the ...

Страница 3: ...w direction is dependent on application For up flow horizontal applications air flow is from the humidifer to return air duct For down flow applications air flow is to the humidifier from the supply air duct 1 Left hand air inlet outlet shown For right hand inlet outlet rotate humidifier cabinet 180º top for bottom and relocate solenoid valve and drain to alternate location on cabinet See Installa...

Страница 4: ...ormation www lennoxdavenet com Contact us at 1 800 4 LENNOX NOTE Due to an ongoing committment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause property damage or personal injury Installation and service must be performed by a qualified installer and servici...

Отзывы: