Health O Meter 2650KL Скачать руководство пользователя страница 26

26 

WARRANTY 

Limited Warranty 

What does the Warranty Cover? 

These Health o meter® Professional scales are warranted from date of purchase against defects of materials or in 
workmanship for a period of two (2) years. If product fails to function properly, return the product, freight prepaid and 
properly packed to Pelstar, LLC (see “To Get Warranty Service”, below, for instructions). If the manufacturer 
determines that a defect of material 

or in workmanship exists, the customer’s sole remedy will be replacement of the 

scale at no charge. Replacement will be made with a new or remanufactured product or component. If the product is 
no longer available, replacement may be made with a similar product of equal or greater value. All replaced parts are 
covered only for the original warranty period. 

Who is Covered? 

The original purchaser of the product must have proof of purchase to receive warranty service. Please save your 
invoice or receipt.  Pelstar dealers or retail stores selling Pelstar products do not have the right to alter, or modify or 
any way change the terms and conditions of this warranty. 

What is Excluded? 

Your warranty does not cover normal wear of parts or damage resulting from any of the following:

 negligent 

use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, abuse 
including tampering, damage in transit, or unauthorized repair or alternations. Further, the warranty does not cover 
natural disasters, such as fire, flood, hurricanes and tornadoes. This warranty gives you specific legal rights, and you 
may also have other rights that vary from country to country, state to state, province to province or jurisdiction to 
jurisdiction. 

To get Warranty Service make sure you keep your sales receipt or document showing proof of purchase. 

Call 

(+1) 800-638-3722 or (+1) 708-377-0600 to receive a return authorization (RA) number, which must be included on 
the return label. Attach your proof of purchase to your defective product along with your name, address, daytime 
telephone number and description of the problem. Carefully package the product and send with shipping and 
insurance prepaid to:

 

Pelstar, LLC 
Attention R/A#_____________ 
Return Department 
9500 West 55

th

 Street  

McCook, IL 60525 

 
Extended Warranty Available 

This product is eligible for Health o meter® Professional ScaleSurance Extended Warranty Program. ScaleSurance 
extends the warranty period for an additional two years. This extension to the standard Limited Warranty can be 
purchased with new products or for a facility’s existing product before its current warranty has expired. To learn more, 
visit www.homscales.com/scalesurance/ or contact your medical supply distributor. 

 

 

PELSTAR, LLC 

9500 West 55

th

 Street 

• McCook, IL 60525 • USA 

1-800-638-3722 or 1-708-377-0600 

PLEASE REGISTER YOUR SCALE FOR WARRANTY COVERAGE AT: www.homscales.com  

 

Health o meter® is a registered trademark of Sunbeam Products, Inc. used under license. 

Health o meter® Professional products are manufactured, designed, and owned by Pelstar, LLC. 

We reserve the right to improve, enhance, or modify Health o meter® Professional product features or specifications 
without notice. 

© Pelstar, LLC 2018 

 

 

 

P/N UM2650KL_2650KG_2700KL_2700KG_E_REV20180625

 

Содержание 2650KL

Страница 1: ...Wheelchair Scales User Instructions PELSTAR LLC 9500 West 55 th St McCook IL 60525 7110 USA www homscales com Pelstar LLC 2018 P N UM2650KL_2650KG_2700KL_2700KG_E_REV20180625 Equipped with Everlock E...

Страница 2: ...ounting Instructions 8 Powering the Scale 10 Set Up Instructions 11 Everlock Instructions 14 Operating Instructions 15 Transport Instructions 21 Maintenance and Cleaning 22 Calibration 23 Troubleshoot...

Страница 3: ...AC adapter cord for cracking fraying or for broken bent plug prongs Prior to using this scale ensure that the AC adapter is plugged into an outlet with the rated voltage appropriate for operation Ens...

Страница 4: ...0 lb x 0 2 lb 454 kg x 0 1 kg 2650KG 2700KG 454 kg x 0 1 kg Power Requirements 100 240V AC 50 60Hz to 9V DC Adapter Type UE15WCP 9 VDC 500 mA Item ADPT30 included or 6 D batteries not included Environ...

Страница 5: ...to other electronic devices please contact Health o meter Professional Scales Technical Support available during normal business hours at 1 800 638 3722 Scale Disposal Health o meter Professional scal...

Страница 6: ...ly remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any...

Страница 7: ...level the scale Be certain that the feet are not completely tightened into the platform for proper load cell operation Open the scale to its operational position by unfolding the wheelchair ramps 3 C...

Страница 8: ...or placed on a table up to 71 1 8 m from the platform 1 Place the display head with its attached mounting bracket mount on the wall in the desired location Ensure that the display head is level and th...

Страница 9: ...1 8 3 2 mm from the wall Warning Extending the screw heads beyond 1 8 3 2 mm can damage the display assembly 6 Obtain the display head and the load cell cable Plug the load cell cable into the load c...

Страница 10: ...unscrewing the battery cover screw 2 Remove the battery pack from the display head Replace or install fresh batteries making sure to install them in the proper direction Health o meter Professional re...

Страница 11: ...is locked per the instructions above users can still view the alternate weight measuring unit by enabling the Unit View option Enabling the Unit View option allows the user to press the Unit button t...

Страница 12: ...time of inactivity before power off 1 Press to access the Help menu options 2 While in the Help menu press to select Set Options Press to advance to the next menu 3 While in the Set Options sub menu p...

Страница 13: ...n powered on rather it will use the last zero setting it had from its most recent use There will be no delay in using the scale if the Auto Zero is disabled Health o meter Professional recommends that...

Страница 14: ...1 800 815 6615 1 Press to access the Help menu options 2 While in the Help menu press to select Set Options Press to advance to the next menu 3 While in the Set Options sub menu press to scroll throu...

Страница 15: ...f a weight value to be deducted from the weight on the platform Also releases tare weight returns display to zero Toggles between pounds and kilograms If weight measuring unit is locked and Unit View...

Страница 16: ...ared weight of the object from the gross weight of the patient and object together The display will show the patient s weight 5 With no weight on the scale the display will show the tare value as a ne...

Страница 17: ...ent The display will show the patient s weight 5 The weight may be held on the display by pressing The scale will continue to display the patient s weight after they are off the scale and will remain...

Страница 18: ...on the display by pressing The scale will continue to display the patient s weight after they step off the scale and will remain on the display until released or the scale is powered off To release p...

Страница 19: ...patient remaining on the scale press 3 The scale will prompt entry of the patient s height Use the arrow keys to enter the patient s height Note When weighing in pounds the height is displayed in inch...

Страница 20: ...e parent s tared weight 4 Carefully place the child into the parent s arms The scale will automatically deduct the weight of the parent and only display the child s weight Note For an alternate method...

Страница 21: ...off of the mounting screws 3 Unplug the load cell cable from the scale platform and the display head Carefully store the load cell cable during transport 4 With the scale laying flat on the floor fold...

Страница 22: ...sinfecting Proper care and cleaning is essential to ensure a long life of accurate and effective weighing Caution Disconnect the scale from the AC adapter power source prior to cleaning the unit 1 Hea...

Страница 23: ...s should be used for calibration Warning Always ensure that the scale is returned to the correct UOM after scale calibration 1 Press to access the Help menu options 2 While in the Help menu press to s...

Страница 24: ...ibration weights to be placed on the platform Press after calibration weights are placed on the platform 9 The display will show Calibrating during the calibration process 10 If calibration is success...

Страница 25: ...balanced Completely hand tighten the feet then turn them back 1 full turns 4 Scale is out of calibration 4 Check weight with known weight value Weighing is performed but the weighing process takes too...

Страница 26: ...This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty S...