background image

 

Parts 

No. 

Description Qty.

Parts 

No. 

Description Qty.

Plastic upper cover 

40 

Washer 

2 Bow 

plastic 

cover 1 

41 

Stick 

3 Support 

point 1 

42 

Axis 

X Stick label 

43 

Whorl 

Y Stick label 

44 

O washer 

Symbol label 

48 

Encode PCB 

Caution label A 

53 

Washer 

Caution label B 

85 

Operating panel 

Waterproof rubber A 

86 

Frame support 

10 

Beam window 

88 

Frame support 

13 

Window supporter 

89 

Rubber seal 

14 

Waterproof rubber B 

90 

S/N stick 

15 

Decorative rubber   

91 

Plastic housing 

16 Bubble 

vial  1 

94 

Keypad 

17 

Upward window 

95 

Cable A 

18 Drawtube  1 

96 

Cable 

20 

Sensor support 

97 

Base body 

21 Lens  1 

102 

Plastic 

cover 1 

22 

Quoit screw 

103 

Waterproof rubber 

23 Spring  1 

104  Lock 

pin 

24 

Main frame 

105 

Battery spring(single) 

25 

Motor frame 

106 

Battery spring(double) 

26 

Universal bearing 

108 

Metal cover 

27 

Plastic supporter 

111 

Battery cable 

28 

Limiting joint 

112 

Main control PCB 

29 

L  supporter 

130 

Screws 

30 Pin  2 

132  Screws  4 

31 Rotation 

head  1 

135 

Screws 

32 Penta 

prism  1 

137 

Screws 

33 Rotation 

axis  1 

140 

Screws 

34 Plastic 

gear  1 

142 

Screws 

35 Plastic 

encode  1 

144 

Screws 

36 Whorl  1 

156  Bearing 

37 Adjusting 

whorl  1 

A001

Rechargeable battery Box 

(115,118,120,121,126,127,128,129,131,154) 

38 

Whorl 

A002

Normal battery box 

39 

Cuneal lens 

A003

Adjusting screw system 

B001 

Laser module 

A004

Y motor system 

B002 

Sensor module 

A005

X motor system 

B003 

Rotation part module 

A006

Rotation motor module 

B004 

Penta prism module 

B005

Cover assembly 

 

 

 

Содержание SP50

Страница 1: ...Maintenance Manual Issued 18th Feb 2006 Revised Auto Laser Level SP50 SP50A Changzhou Huada Kejie Opto Electro Instrument Co Ltd ...

Страница 2: ...aser diode from short life time caused by static electricity in the unit 1 Before disconnecting the plugs of the laser unit from the jack turn power switch off 2 Don t touch the PCB of laser unit by hand 3 Use special battery as power supply Avoid as possible to use AC DC stabilizer 4 Don t operate to switch ON OFF repeatedly during short time The PCB of the unit replacing and the compensator repa...

Страница 3: ...1 3 Spare parts and Figures ...

Страница 4: ...B001 ...

Страница 5: ...t screw 1 103 Waterproof rubber 1 23 Spring 1 104 Lock pin 2 24 Main frame 1 105 Battery spring single 1 25 Motor frame 1 106 Battery spring double 1 26 Universal bearing 1 108 Metal cover 1 27 Plastic supporter 1 111 Battery cable 1 28 Limiting joint 1 112 Main control PCB 1 29 L supporter 1 130 Screws 6 30 Pin 2 132 Screws 4 31 Rotation head 1 135 Screws 4 32 Penta prism 1 137 Screws 1 33 Rotati...

Страница 6: ...canning Rotation Motor Y Step Motor X Step LD Module Y Range Limiting X Range Limiting Keypad A Keypad B Sensor X Sensor Y Sensor Z Step Motor Y LD Module Y Range Step Motor X X Range Scanning Rotation Motor Sensor X Sensor Y Sensor Z ...

Страница 7: ... adjusting parts A004 A005 remove the screws which fix the rotating motor module A006 Take off A006 Remove four screws which fix 112 and take off main control PCB 112 1 5 Flow chart for trouble diagnosis 1 5 1 Description After adjusting unit not to be leveling After turning on the unit the unit will not stop making leveling and laser beam will blink and will not rotate 1 5 2 After inclining unit ...

Страница 8: ...If the marks are not close enough more than 2mm the X direction needs to be calibrated Check the Y direction same way as X direction 2 2 Vertieal accuracy checking Put the unit in vertical direction and place it on a flat plate 3m away from a plumb line Hanging a ball in a wire with height 2 5m apart from the unit If the unit needs calibration it is better in a dark room Adjusting the foot screws ...

Страница 9: ...ress the key CAL to change to Y Calibration Y indication light blinking Calibrating Y is same way as calibrating X After calibrating Y press the key CAL to save the data and to go back to normal operation from calibrating Then press the key I O to turn off the unit 3 2 Vertical accuracy calibrating Put the unit in vertical Turn on the unit After leveling press the key CAL for five seconds Then Z i...

Отзывы: