1-4 Procedure for Assembling unit A001 module
①
Remove rechargeable battery box
②
Use cross screw driver to remove four L1 screws from fixed cover module B005. Take off B005.
③
Use cross screw driver to remove four L2 screws which fix the housing and base. Take off 23 from
the mechanism unit.
④
Take off the plug from mechanism module
⑤
Remove three L3 screws. Then , remove two L4 screws. Turn and take off 48
⑥
Remove the pentagonal prism module B004 from the mechanism module.
⑦
Turn and take off 43 with the tweezers and remove 44. Then remove the rotating part B003.
⑧
Turn and take off four L5 screws. Then, take off X/Y axis adjusting parts A004/A005.
⑨
remove the screws which fix the rotating motor module A006. Take off A006.
⑩
Remove four screws which fix 112 and take off main control PCB 112.
1-5 Flow chart for trouble diagnosis
1-5-1 Description: After adjusting, unit not to be leveling. After turning on the unit, the unit will not stop
making leveling and laser beam will blink and will not rotate.
1-5-2 After inclining, unit to be alarming
Description: When unit placing on flat surface and turning on, the unit will incline to one side and the
laser beam will blink. At same time the unit will be alarming.
Unit is not making leveling
Replace Main PCB 112
NG
Return to manufacturer for repairing
OK
Unit to be alarming when unit tilting
Replace A004/A005 module
OK
OK
NG
Replace main PCB 112
NG
Return to the manufacturer for repair