Страница 1: ...Maintenance Manual Issued 18th Feb 2006 Revised Auto Laser Level SP50 SP50A Changzhou Huada Kejie Opto Electro Instrument Co Ltd ...

Страница 2: ...aser diode from short life time caused by static electricity in the unit 1 Before disconnecting the plugs of the laser unit from the jack turn power switch off 2 Don t touch the PCB of laser unit by hand 3 Use special battery as power supply Avoid as possible to use AC DC stabilizer 4 Don t operate to switch ON OFF repeatedly during short time The PCB of the unit replacing and the compensator repa...

Страница 3: ...1 3 Spare parts and Figures ...

Страница 4: ...B001 ...

Страница 5: ...t screw 1 103 Waterproof rubber 1 23 Spring 1 104 Lock pin 2 24 Main frame 1 105 Battery spring single 1 25 Motor frame 1 106 Battery spring double 1 26 Universal bearing 1 108 Metal cover 1 27 Plastic supporter 1 111 Battery cable 1 28 Limiting joint 1 112 Main control PCB 1 29 L supporter 1 130 Screws 6 30 Pin 2 132 Screws 4 31 Rotation head 1 135 Screws 4 32 Penta prism 1 137 Screws 1 33 Rotati...

Страница 6: ...canning Rotation Motor Y Step Motor X Step LD Module Y Range Limiting X Range Limiting Keypad A Keypad B Sensor X Sensor Y Sensor Z Step Motor Y LD Module Y Range Step Motor X X Range Scanning Rotation Motor Sensor X Sensor Y Sensor Z ...

Страница 7: ... adjusting parts A004 A005 remove the screws which fix the rotating motor module A006 Take off A006 Remove four screws which fix 112 and take off main control PCB 112 1 5 Flow chart for trouble diagnosis 1 5 1 Description After adjusting unit not to be leveling After turning on the unit the unit will not stop making leveling and laser beam will blink and will not rotate 1 5 2 After inclining unit ...

Страница 8: ...If the marks are not close enough more than 2mm the X direction needs to be calibrated Check the Y direction same way as X direction 2 2 Vertieal accuracy checking Put the unit in vertical direction and place it on a flat plate 3m away from a plumb line Hanging a ball in a wire with height 2 5m apart from the unit If the unit needs calibration it is better in a dark room Adjusting the foot screws ...

Страница 9: ...ress the key CAL to change to Y Calibration Y indication light blinking Calibrating Y is same way as calibrating X After calibrating Y press the key CAL to save the data and to go back to normal operation from calibrating Then press the key I O to turn off the unit 3 2 Vertical accuracy calibrating Put the unit in vertical Turn on the unit After leveling press the key CAL for five seconds Then Z i...