CDM 3201 Order No. BA 92-12-3321A Issue 19.09.08
5.9
Malfunctions and Corrective Actions
Malfu nction
Possible cause
Fault finding
Corrective action
Carried out by
Light signal of primary
switch does not light
Primary outlet defective
Check primary outlet *)
Replace primary outlet *)
Qualified personnel
Mains cable broken
Check mains cable *)
Replace mains cable *)
Qualified personnel
No LED display at the
front
Fuse F4 10 AT defec tive
Check mains fuse
Replace mains fuse F4 on the
front plate of the power unit
Instructed personnel
Leads interrupted
Check leads *)
Replace leads *)
Qualified personnel
No display
No ground connection
Check ground connection on
workpiece
Tighten ground connection
properly
Instructed personnel
Gun not connected
Check welding gun connection Connect welding gun properly
Instructed personnel
Transition resistance
(between stud and
workpiece) too high
Check material surface
Clean or grind material surface
Instructed personnel
Ground cable broken
Check ground cable *)
Replace ground cable *)
Qualified personnel
Welding gun cable broken Check welding gun cable *)
Replace welding gun cable *)
Qualified personnel
No display
Defective c onnecting line
of welding gun
Check function of connecting
line *)
Replace connecting line *)
Qualified personnel
Welding gun trigger button
defective
Check control cable for
electrical flow with triggered
start button *)
Replace welding gun trigger
button *)
Qualified personnel
Control cable broken
Check control cable for
electrical flow*)
Replace control cable *)
Qualified personnel
Gun does not lift, in
spite of ,
and
No lift adjusted
Check settings of welding gun Modify set parameters
Instructed personnel
Short circuit of solenoid
circuit of the gun
Check resistance value at
control cable (18
to 22
)
between Pin 1 and Pin 2 *)
Replace control cable, c ontrol
line, solenoid *)
Qualified personnel
Solenoid defective
Check solenoid (18
to
22
) *)
Replace solenoid *)
Qualified personnel
No display
Solenoid circuit interrupted Check resistance value at
control cable (18
Ω
to 22
)
between Pin 1 and Pin 2 *)
Replace solenoid or control line
*)
Qualified personnel
Actions marked with *) must only be carried out by qualified
electricians!
If none of the actions is successful, please contact our service
department.
5 Stud Welding Procedure
5.9 Malfunctions and Corrective Actions
Содержание CDM 3201
Страница 1: ...CDM 3201 Power Unit Automatic Version 92 12 3321A Operating Manual...
Страница 8: ...viii CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 Table of Contents...
Страница 87: ...CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 87 Service Support Service Support...
Страница 92: ...92 CDM 3201 Order No BA 92 12 3321A Issue 19 09 08...
Страница 93: ......