34
CDM 3201 Order No. BA 92-12-3321A Issue 19.09.08
Library mode
In library mode, you can call-up charging voltages related to stud diameter and stud
material. If necessary, you can modify the charging voltage. Preset values are only
guidelines. They apply for identical materials of stud and work piece.
Selection of stud diameter
Press the arrow key
until the
sign ">" is displayed to the left of "M x"
>M5 AlMg3 130 V
⇒
increase diameter with
⇒
decrease diameter with
Diameters: M3, M4, M5, M6, M8
Selection of material
Press the arrow key
until the sign ">" points to the material
M5 >AlMg3 130 V
⇒
select material with
or
Materials:
S235
mild steel S235
S235 + Zn galvanized steel (S235 + zinc < 25 µm)
1.4301
stainless steel 1.4301, 1.4303
AlMg3
aluminum AlMg3; AlMgSi0,5
CuZn37
brass (zinc < 37%)
Changing the charging voltage
Press the arrow key
until
the sign ">" appears to the left of "xxx V".
M5 AlMg3 >130 V
⇒
increase charging voltage with
⇒
decrease charging voltage with
Charging voltage: 50 V to 220 V
5 Stud Welding Procedure
5.6 Switching on the Power Unit
Содержание CDM 3201
Страница 1: ...CDM 3201 Power Unit Automatic Version 92 12 3321A Operating Manual...
Страница 8: ...viii CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 Table of Contents...
Страница 87: ...CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 87 Service Support Service Support...
Страница 92: ...92 CDM 3201 Order No BA 92 12 3321A Issue 19 09 08...
Страница 93: ......