CDM 3201 Order No. BA 92-12-3321A Issue 19.09.08
LED's
If you are working with process sequence control, see section 5.6.4, then the LED’s
inform whether the PAF value is inside the tolerance range of the reference or not.
Green
value inside of adjusted tolerance range
Red
value out of adjusted tolerance range
Basic settings
You can set the machine according to your requirements. Call-up the main menu with
the Enter key
. The following menu items are available:
– Automatic
Setting air pressure time for VBZ and tappet
– Mode
Selection between program and library mode
– Control
Activation of process sequence control
– Language
Selection of language
– Welding gun
Lift test of drawn-arc welding gun
– Service
Time and date setting
– Reset
Reset to HBS standard settings
– Thyristor
Capacity switch (CDM 2401/CDM 3201/SCD 3201))
– Gas
Setting of gas pre-flow time (SCD 3201)
Basically, you select a menu item with the arrow key
and then you open it with
the enter key
. Confirmation of settings and quitting the menu item is also carried
out with the enter key
.
5.6.1
Adjusting the Charging Voltage of Capacitors
Refer to the table in section 5.5 for the required charging voltage matching your
welding job.
Select the menu item charging voltage with the arrow key
.
Set the charging voltage (LCD display) with the two arrow keys
(
) on the display.
P5 >150 V
5 Stud Welding Procedure
5.6 Switching on the Power Unit
Содержание CDM 3201
Страница 1: ...CDM 3201 Power Unit Automatic Version 92 12 3321A Operating Manual...
Страница 8: ...viii CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 Table of Contents...
Страница 87: ...CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 87 Service Support Service Support...
Страница 92: ...92 CDM 3201 Order No BA 92 12 3321A Issue 19 09 08...
Страница 93: ......