Electrical connection
34
A4429-3.0
HBM: public
T40FH
Notice
Torque flanges are only intended for operation with a DC supply voltage. They
must not be connected to older HBM amplifiers with square-wave excitation.
This could destroy the connection board resistors or cause other faults in the
amplifiers.
Assignment for connector 2 - rotational speed measuring system
6
1
5
7
2
4
3
8
Device plug
Top view
KAB154
KAB150
KAB179
Con
nector
pin
Assignment
Color
code
D-SUB
connector
pin
HD-SUB
connector
pin
1
(pulse string, 5V; 0
°
)
rd
12
10
2
Not in use
bu
-
-
3
(pulse string, 5 V; 90
°
phase
shifted)
gy
15
8
4
Not in use
bk
-
-
5
Not in use
vt
-
-
6
(pulse string, 5V; 0
°
)
wh
13
5
7
Speed measurement signal
(pulse string, 5 V; 90
°
phase
shifted)
gn
14
7