T12
A1979
−
10.0 en
HBM
Nominal (rated) torque
M
nom
N
m
100
200
500
kN
m
1
General information
EMC
Emission (per FCC 47 Part 15, Subpart C)
−
Emission
(per EN61326
−
1, Table 3)
RFI voltage
−
Class A
RFI power
−
Class A
RFI field strength
−
Class A
Immunity from interference
(EN61326
−
1,
Table A.1)
Electromagnetic field (AM)
V/m
10
Magnetic field
A/m
30
Electrostatic discharge (ESD)
Contact discharge
kV
4
Air discharge
kV
8
Fast transients (burst)
kV
1
Impulse voltages (surge)
kV
1
Conducted interference (AM)
V
3
Degree of protection per EN 60529
IP 54
Reference temperature
C
23
Nominal (rated) temperature range
C
+10 to +60
Operating temperature range
C
−
10 to +60
Storage temperature range
C
−
20 to +70
Impact resistance, test severity level
according to DIN IEC 68; Part 227; IEC
682271987
Number
n
1000
Duration
ms
3
Acceleration (half sine)
m/s
2
650
Vibration in 3 directions according to
EN 60068
−
2
−
6: IEC 68-2-6-1982
Frequency range
Hz
5 to 65
Duration
h
1.5
Acceleration (amplitude)
m/s
2
50
Load limits
7)
Limit torque, (static)
"
% of
M
nom
200
Breaking torque, (static)
"
% of
M
nom
> 400
Longitudinal limit force (static)
"
kN
5
10
16
19
Longitudinal limit force (dynamic) amplitude
kN
2.5
5
8
8.5
Lateral limit force (static)
"
kN
1
2
4
5
Lateral limit force (dynamic) amplitude
kN
0.5
1
2
2.5
Limit bending moment (static)
"
N
m
50
100
200
220
Limit bending moment (dynamic) amplitude
N
m
25
50
100
110
Oscillation width per DIN 50100
(peak-to-peak)
8)
N
m
200
400
1000
2000
7)
Each type of irregular stress (bending moment, lateral or longitudinal force, exceeding nominal (rated) torque)
can only be permitted up to its specified limit provided none of the others can occur at the same time. If this
condition is not met, the limit values must be reduced. If 30% of the limit bending moment and lateral limit
force occur at the same time, only 40% of the longitudinal limit force is permissible and the nominal (rated)
torque must not be exceeded. The effects of permissible bending moments, longitudinal and lateral forces on
the measurement result are
v"
0.3% of the nominal (rated) torque.
8)
The nominal (rated) torque must not be exceeded.