Scope of supply
Load cell with connection cable, Mounting Instructions
2
Mounting
Please pay attention on the following points fo
r
the mounting of load
cells:
S
Do not overload load cells, not even temporarily.
S
The mounting surface must be horizontal, flat across the entire surface, and
absolutely clean. Dust, dirt, and other foreign matter should not collect such
that they have a detrimental effect on the mobility of load cells, thus
falsifying the measured value.
S
W
hen mounting, or immediately after mounting, each load cell should be
bridged by means of a twisted copper cable (e.g.
EEK...
by
HBM
= approx.
16 mm
2
). In this way, you prevent damage caused by welding currents.
S
Load cell grounding reduces the risk of load cell damage due to lightning.
ATTENTION
Neve
r
load in a di
r
ection opposite to the load di
r
ection specified (see
a
rr
ow on the load int
r
oduction f
r
ont of the load cell). This would cause
measu
r
ement e
rr
o
r
s and the damage of the mounting bolts. If load
di
r
ection is co
rr
ect, the load cell output signal is positive.
load direction
base plate
load direction
The base plate should be made from stainless steel, with a Rockwell hardness of 42.
The surfaces X" must be even and in parallel (0.25 mm).
base plate
See table for bolt
tightening torque.
h
x
x
x
x
h
Содержание BLC B Series
Страница 2: ...English Page 3 20 Deutsch Seite 21 38 Fran ais Page 39 55...
Страница 20: ...20 HLC BLC ELC HBM A1130 3 1 en de fr...