1.

 

Proceed as follows in order to cool down the unit and empty 
the mould (mould evacuation) 

  Display menu page 

Functions

  Select the function 

Cooling

 and activate with the 

 key. 

  Select the function 

Mould evacuation

 and activate with the 

 

key. 

 The activated function is indicated with the 

 symbol. 

 

 

2.

 

Main switch off, remove the plug from the mains and empty 
the unit. 

 

 

3.

 

Remove control cable to ext. flow rate meter Flow-5. 

  

 

 

Fig. 1: Front side of the evaluation unit 

 

Fig. 2: Rear side of the evaluation unit 

 

4. 

Proceed as follows in order to remove the cover of the 
evaluation unit: 

 

Remove screws (Label 1 

 Fig. 1). 

 

Detach screws (Label 2 

 Fig. 2). 

 

Lift the cover with the keyboard and pull out the ribbon cable. 

 

Remove the cover with the keyboard. 

 

   

 

 

Fig. 3: DFM-51 evaluation unit  

5.

 

Proceed as follows in order to replace the printed circuit board 
DFM-51 (A 9): 

  Pull out plug connections of printed circuit board DFM-51. 

  Remove screws (Label 3 

 Fig. 3). 

  Remove printed circuit board DFM-51 and insert new one in the 

evaluation unit. 

 

Attach screws (Label 3 

 Fig. 3). 

 

Connect plug connections to the printed circuit board. 

    

 

1

2

3

Содержание T24693

Страница 1: ...on for carrying outconversion work on the unit Procedure DANGER Danger to life caused by electric current Touching conductive parts causes a direct danger to life Therefore For all work on the electri...

Страница 2: ...1 Front side of the evaluation unit Fig 2 Rear side of the evaluation unit 4 Proceed as follows in order to remove the cover of the evaluation unit Remove screws Label 1 Fig 1 Detach screws Label 2 F...

Страница 3: ...o the keyboard and attach the cover Attach screws Label 1 Fig 4 Tighten screws Label 2 Fig 5 7 Connect control cable to ext flow rate meter Flow 5 8 Reconnect mains plug and switch on main switch 9 Sw...

Страница 4: ...configuration 10 Proceed as follows to assemble the new printed circuit board DFM 51 A 9 Change to the next screen page with the key Configure ext flow rate meter information on the rating plate Selec...

Страница 5: ...et corresponding parameter Flow rate ext 1 8 Calibration at Service Calibration Flow rate external 1 to 4 or Service Calibration Flow rate external 5 to 8 to ON The flow rate is calibrated automatical...

Страница 6: ...fected e g A1 with the or buttons Set parameter Flow rate calibration at Service Calibration Flow rate to ON The flow rate is calibrated automatically Only in the case of water devices If present set...

Страница 7: ...if necessary the temperature sensor With a constant deviation set parameter Sensor offset under Service Calibration Temperature With a linear deviation set parameter Sensor asc cor under Service Calib...

Страница 8: ...M8100 EN 2018 03 8 8 Parts list Pos Description O ID Pcs 01 Flow rate measuring board DFM 51 T24693 1 02 Assembly instructions German M8100 DE 1 03 Assembly instructions English M8100 EN 1 04 Assembly...

Отзывы: