Assembly Instructions M8100-EN
M8100-EN 2018-03
7/8
16.
Proceed as follows in order to calibrate the temperature
sensor:
When setting partameters set
DFM recognition
to the
"integrated“ value (in
Settings / Various)
, continue with Step
When setting parameters set
DFM recognition
to the "modular“
value (in
Settings / Various)
Fig. 11: Sensor calibration during
integrated operation
Integrated operation
17.
Temperature sensor main line ext 1..8 and temperature
sensor return line ext. Proceed as follows in order to calibrate
1..8 , if necessary, the temperature sensor:
With a constant deviation set parameter
Sensor… offset
under
Service / Calibration / Temperature
.
With a linear deviation, set parameter
Sensor… asc.cor.
under
Service / Calibration / Temperature
.
Fig. 12: Sensor calibration during modular
operation
Operation Modular
18.
Proceed as follows, if necessary calibrate the temperature
sensor for the main line and temperature sensor of the return
line:
Select the module affected e.g. "A1“ with the
or
buttons.
With a constant deviation set parameter
Sensor… offset
under
Service / Calibration / Temperature
.
With a linear deviation, set parameter
Sensor… asc.cor.
under
Service / Calibration / Temperature
.
19.
Check unit functions.
20.
Switch the unit off by press the
key.
21.
Main switch off.