9
Use Only Genuine Hayward Replacement Parts.
Operating the Viio Turbo Cleaner
9
Warning - Risk of Injury
The Filtration and Booster Pumps must be
OFF
when
connecting or disconnecting cleaner hose.
Caution - Risk of Equipment Damage
The filter pump must always be run to clear air from the system
before turning the Booster Pump
ON. Never run
the Booster
Pump without the main filter pump
ON
. Running the Booster
Pump dry will damage the Booster Pump and void the warranty.
Operating the Viio Turbo Cleaner
1.
Be sure all filtration system valves are open and
supplying water to the Booster Pump.
2.
Be sure valves to and from the Booster Pump and
dedicated return line are fully opened.
3.
The Viio Turbo Cleaner and its Booster Pump can
only operate when the pool’s filter pump is operating.
Caution - Risk of Equipment Damage
Failure to open valves fully and/or failure to have the
filtration system operating will damage the Booster
Pump. This damage voids the Booster Pump’s warranty.
Setting Pressure
Important:
The cleaner will not operate properly if the
pressure is not properly set. Too little pressure will prevent
proper movement and cleaning. Too much pressure will
cause poor cleaning and premature wear of Cleaner parts.
Warning - Risk of Injury
Be careful to hold the Cleaner Connector (Part C) with the
Setup Pressure Gauge (Part U) attached under water and not
to be sprayed by the hole in the Setup Pressure Gauge or by
the Sweep Hose.
Never
point a jet or hose at people or pets.
Clip the Setup Pressure Gauge to the hose near the Wall
Quick Connect.
1.
Turn the filtration system pump
ON
then the
Booster Pump
ON
. Read the pressure on the Setup
Pressure Gauge connected to the Cleaner
Connector. Use a flat blade screwdriver to adjust the
Wall Quick Connect Knob (see figure 2) until the
pressure reads 25 PSI (+/- 5 PSI) (1,7 Bar +/- 0,3 Bar).
Note:
The Wall Quick Connect can be adjusted from
“0” (fully closed) to “5” (fully open). Do
NOT
force
the adjustment knob beyond “0” or “5”.
2.
If the Wall Connector is on Position “5” (fully open)
and the pressure is still below 1.4 bar (20 PSI),
check for clogged Filter, Pump Strainer Basket, Main
Drain, Skimmer Basket, etc., to determine why there
is insufficient water pressure at the dedicated line. If
more pressure is still required have an Authorized
Hayward Pool Dealer or Service person check the
Booster Pump, Filtration System and Plumbing to
determine if they are functioning correctly.
3.
Turn the Booster Pump and Filtration Pump
OFF
.
4. Remove the Setup Pressure Gauge
from the
Cleaner Connector. Store the Setup Pressure Gauge
with the Owner’s Guide in a safe place.
5.
Attach the Cleaner Connector to Cleaner. The Sweep
Hose should be directly below the Pressure Hose.
6.
Place the cleaner in the pool, turn the Filtration
system
ON
, then turn the Booster Pump
ON
.
Connecting Pressure Hose to Cleaner
Adjusting Pressure at Wall Connector
Setup Pressure Gauge & Wall Connect