![Hayward TriStar SP322063EEV Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/hayward/tristar-sp322063eev/tristar-sp322063eev_owners-manual_2111224007.webp)
TriStar Variable Speed Pump Control ____ ____________________________Page 7 of 16
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Operation & Setup
VARIABLE SPEED INTERFACE – INSTALLER INITIAL SETUP
1
:
Event
Performed function
Keypad active functions
Display message
Initial Power On.
Or
Initial Setup Override
(pressing 4 during
Power On).
System checks to
determine if initial
setup parameters were
previously set. If not,
system enters Select
Language step of initial
setup procedure.
Press Time Up/Dn button to
select desired language. Press 6
(OK) to store current settings.
SELECT LANGUAGE
*ENGLISH
*ESPANOL
*FRANCAIS
Language selection is
complete.
Clock setup.
Press 5 (Next) or 2 (Previous)
buttons to select day of week,
hours, and minutes settings.
Press Time Up/Dn buttons to
change the selected value
(selected value will be displayed
with underlining cursor). Press
6 (OK) to store current settings.
CHECK THE CLOCK
*SET Mon 12:50pm
Clock setting is
complete.
Prime Mode setup.
Press Time Up/Dn buttons to
select desired prime mode
2
(prime mode should be selected
based on height of pump inlet
above water level in pool).
Press 6 (OK) to store current
settings.
PICK PRIME MODE
*MORE THAN 5 FT
*5 FEET OR LESS
Prime mode selection
is complete.
Timer disabled:
pump
runs according to prime
mode selected, and
defaults to P2.
Timer enabled:
pump
remains stopped until
system time reaches
TimerOn setting.
Use 1 – 6 buttons to switch
pump to a preset mode. Use
Time Up/Dn buttons to cause
remaining time for current mode
to increase/decrease by 5
minutes. Use % Flow Up/Dn
buttons to change pump speed
within predefined range.
*PRIME MODE*
(when timer is disabled)
*PUMP STOPPED*
(when timer is enabled, until
system time reaches TimerOn
setting)