TriStar Variable Speed Pump Control ____ ____________________________Page 12 of 16
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
POOL & SPA CONTROLLER – BASIC OPERATION
3
:
Event
Performed function
Keypad active functions
Display message
Power Off
RTC
4
operation only.
All inactive
>OFF<
Power On
Configuration OK
Check configuration
and proceed to Stop
Mode.
System enters Stop Mode until
RTC
4
reaches Timer On time, or
the user selects a preset on the
keypad. All other functions are
disabled.
HAYWARD POOL&SPA
*VERSION 1.27*
*PUMP STOPPED*
Stop Mode
Pump is stopped until
RTC
4
reaches Timer
On time, or the user
selects a preset on the
keypad.
Buttons 16 are active. When
the user selects a preset on the
keypad, the system enters Prime
Mode. After priming, the
system operates according to the
preset that was selected.
*PRIME > *P3
*PRIME > *P1
Prime Mode
Pump will prime first
when a preset is
selected during Stop
Mode.
Pressing Time Up/Dn causes
remaining time for Prime Mode
to be displayed.
Pressing 16 changes the preset
which will be activated upon
completion of Prime Mode.
Pressing Flow Up/Dn displays
pump speed. Pump speed
cannot be changed during Prime
Mode.
8 min REMAINS
*PRIME > *P4
PUMP SPEED 85%
End of prime
Operate according to
active mode with flow
set for this mode and
for preset time.
After Prime Mode is completed,
the pump will operate according
to the preset that was selected,
and will reenter Stop Mode
when the preset expires.
P4. MEDIUMHIGH
(P4 indicates preset #4)
Timer activates the
system.
The system enters
OnPeriod
System enters Prime
Mode if the pump was
stopped prior to On
Period, or system enters
first sequence step if
pump was running prior
to OnPeriod.
*TIMER IS=ON*
*PRIME MODE*
S1 8:40am *P3
(S1 indicates sequence step #1;
8:40am is current time; *P3 is
currently running preset defined
in sequence step S1)
System operates
during OnPeriod
System advances
through sequence steps
unil RTC
4
reaches
TimerOff time. If
sequence steps end
before TimerOff time
is reached, system will
default to P2 “Low
Filter” speed.
% Flow and Time buttons as
well as 16 buttons are active.
The % Flow and Time buttons
may be used to temporarily
change the flow and time of the
current sequence step. The 16
buttons may be used to
temporarily override the current
sequence step. The system will
operate according to the selected
preset and will advance to the
next sequence step when the
preset expires.
S1 8:40am *P4
(where *P4 is manually selected
preset which overrides the
current sequence step)