Hayward TriStar SP322063EEV Скачать руководство пользователя страница 3

TriStar Variable Speed Pump Control   ____                      ____________________________Page 3 of 16 

WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

WARNING 

Risk of Electric Shock.

  All electrical wiring MUST be in conformance with 

applicable local codes, regulations, and the National Electric Code (NEC).  Hazardous voltage can shock, 
burn, and cause death or serious property damage.  To reduce the risk of electric shock, do NOT use an 
extension cord to connect unit to electric supply.  Provide a properly located electrical receptacle.    Before 
working on pump or motor, turn off power supply to the pump.

 

WARNING 

 

To reduce the risk of electric shock replace damaged wiring immediately.  Locate conduit to prevent abuse 

from lawn mowers, hedge trimmers and other equipment.

 

WARNING 

 

Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or 

death.  To reduce the risk of electric shock, see installation instructions and consult a professional electrician on how to bond pump. 
Also, contact a licensed electrician for information on local electrical codes for bonding requirements.

 

Notes to the electrician:

  Use a solid copper conductor, size 8 or larger.  Run a continuous wire from external bonding lug to 

reinforcing rod or mesh.  Connect a No. 8 AWG (8.4 mm 

) solid copper bonding wire to the pressure wire connector provided on the 

motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas 
piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub.

  IMPORTANT ­

Reference NEC codes for 

all wiring standards including, but not limited to, grounding, bonding and other general wiring procedures.

 

CAUTION:

  The equipment and controls shall be located not less than 1 M horizontally from the spa or hot tub.

  ATTENTION:

 

Maintenir une distance minimale, mesuree dans un plan horizontal, de 1 M entre la cuve de relaxation et les appareils et commandes.

 

CAUTION:

  When required by the Canadian electrical code, part I, section 68, connect only to a circuit protected by a class A ground 

fault circuit interrupter.

  ATTENTION:

  Si l'installation est visee par la section 68 du code Canadien de l ielectricite, premiere partie, 

brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A.

 

WARNING 

– 

Suction Entrapment Hazard.

 

Suction in suction outlets and/or suction outlet covers which are damaged, broken, cracked, missing, or 
unsecured cause severe injury and/or death due to the following entrapment hazards:

 

Hair Entrapment

­ Hair can become entangled in suction outlet cover.

 

Limb Entrapment

­ A limb inserted into an opening of a suction outlet sump or suction outlet cover that 

is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling 
of the limb.

 

Body Suction Entrapment

­ A differential pressure applied to a large portion of the body or limbs can result in an 

entrapment.

 

Evisceration/ Disembowelment

­ A negative pressure applied directly to the intestines through an unprotected suction outlet 

sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in 
evisceration/disembowelment.

 

Mechanical Entrapment

­ There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be caught 

in an opening of a suction outlet cover resulting in mechanical entrapment.

 

WARNING

 

­

 

To Reduce the risk of Entrapment Hazards:

 

­ When outlets are small enough to be blocked by a person, a minimum of two functioning suction 
outlets per pump must be installed.  Suction outlets in the same plane (i.e. floor or wall), must be 
installed a minimum of three feet (3’) [0.91 meter] apart, as measured from near point to near 
point. 
­ Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by 
a user. 

­ Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 
­ The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found at the bottom of page 5 
of the TriStar Owner’s Guide (IS3200). 
­ Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. 
­ Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. 
­ In addition to two or more suction outlets per pump installed in accordance with latest IAF (formerly NSPI) standards and 
CPSC guidelines, follow all national, state, and local codes applicable. 
­ Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.

Содержание TriStar SP322063EEV

Страница 1: ...efficient dependable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service...

Страница 2: ...g such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Thoug...

Страница 3: ...ielectricite premiere partie brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outle...

Страница 4: ...and spa circulation system unless filter manual air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Fai...

Страница 5: ...l and motor Use green ground terminal provided under motor canopy or access place use size and type wire required by code Connect control and motor ground terminals to control enclosure ground Bond co...

Страница 6: ...e panel containing control interface by removing two screws Disconnect interface cable from Emerson SK drive and place interface panel in a safe location away from water such that the interface does n...

Страница 7: ...me Up Dn buttons to change the selected value selected value will be displayed with underlining cursor Press 6 OK to store current settings CHECK THE CLOCK SET Mon 12 50pm Clock setting is complete Pr...

Страница 8: ...st make these selections before the system will allow the pump to operate If a mistake is made during the initial setup the user may override the incorrect setup by disconnecting power to the system a...

Страница 9: ...P HARDWARE SETUP CONTROL SETUP SETUP mode continued as above Press 6 OK to enter selected menu option for example LANGUAGE SETUP Press 1 Exit to exit the menu LANGUAGE SETUP ENGLISH SETUP mode LANGUAG...

Страница 10: ...buttons for currently displayed mode number causes desired pump speed to be set within predefined range Using Time Up Dn buttons for currently displayed mode number causes desired time to be set with...

Страница 11: ...the Flow Up Dn buttons may temporarily change for each preset Use 5 Next or 2 Prev to select preset range to be setup For example user stops on preset 6 Maximum Flow Press Flow Up Dn buttons to displa...

Страница 12: ...d during Prime Mode 8 min REMAINS PRIME P4 PUMP SPEED 85 End of prime Operate according to active mode with flow set for this mode and for preset time After Prime Mode is completed the pump will opera...

Страница 13: ...from the control After the pump has primed the Flow and Time Up Dn buttons as well as the 1 6 buttons are active Pressing any of the 1 6 buttons will cause the pump to run temporarily according to the...

Страница 14: ...ons and terminals are properly attached and connected E6 VFD EEPROM ER indicates that internal Emerson EEPROM memory is corrupted In such case the Emerson drive will not hold its predefined configurat...

Страница 15: ...Y HAYWARD GENUINE REPLACEMENT PARTS PRODUCT REGISTRATION Retain For Your Records DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODE...

Страница 16: ...be returned transportation paid to the place of purchase or to the nearest authorized Hayward service center For further Hayward dealer or service center information contact Hayward customer service d...