Hayward TriStar SP322063EEV Скачать руководство пользователя страница 1

P/N: IS3220VSC 

Rev:  B

 

__________________________________________________________________________________________ 

OWNER’S MANUAL

 

INSTALLATION, OPERATION, & PARTS

 

TriStar Energy Solution 

TM 

Variable Speed Pump Control

 

The Hayward TriStar Pump is specifically engineered for the demanding requirements of today’s in­ground swimming pool/spa that is 
equipped with large capacity filters, heaters, and pool cleaning equipment.  The TriStar is a self­priming pump that includes an 
improved seal and impeller design that will provide many years of efficient, dependable, corrosion­free service.  The advanced design 
provides superior performance while reducing maintenance requirements.

  NOTE ­

To prevent potential injury and to avoid 

unnecessary service calls, read this manual carefully and completely.

 

WARNING 

– 

The TriStar ES (Energy Solution) variable speed pump control is designed for use only with 

Hayward SP322063EEV 2.7 THP 3 phase pump.

  Do not use with any other pump models.  Use of this control with any other pump 

model will void warranty.  Refer to TriStar Owner’s Guide (IS3200) for all applicable pump installation, operation, and 
troubleshooting information.

 

SAVE THIS INSTRUCTION MANUAL 

HAYWARD POOL PRODUCTS 

620 DIVISION STREET    ELIZABETH, NJ  07207    (908) 351­5400 

WWW.HAYWARDPOOL.COM

Содержание TriStar SP322063EEV

Страница 1: ...efficient dependable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service...

Страница 2: ...g such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Thoug...

Страница 3: ...ielectricite premiere partie brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outle...

Страница 4: ...and spa circulation system unless filter manual air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Fai...

Страница 5: ...l and motor Use green ground terminal provided under motor canopy or access place use size and type wire required by code Connect control and motor ground terminals to control enclosure ground Bond co...

Страница 6: ...e panel containing control interface by removing two screws Disconnect interface cable from Emerson SK drive and place interface panel in a safe location away from water such that the interface does n...

Страница 7: ...me Up Dn buttons to change the selected value selected value will be displayed with underlining cursor Press 6 OK to store current settings CHECK THE CLOCK SET Mon 12 50pm Clock setting is complete Pr...

Страница 8: ...st make these selections before the system will allow the pump to operate If a mistake is made during the initial setup the user may override the incorrect setup by disconnecting power to the system a...

Страница 9: ...P HARDWARE SETUP CONTROL SETUP SETUP mode continued as above Press 6 OK to enter selected menu option for example LANGUAGE SETUP Press 1 Exit to exit the menu LANGUAGE SETUP ENGLISH SETUP mode LANGUAG...

Страница 10: ...buttons for currently displayed mode number causes desired pump speed to be set within predefined range Using Time Up Dn buttons for currently displayed mode number causes desired time to be set with...

Страница 11: ...the Flow Up Dn buttons may temporarily change for each preset Use 5 Next or 2 Prev to select preset range to be setup For example user stops on preset 6 Maximum Flow Press Flow Up Dn buttons to displa...

Страница 12: ...d during Prime Mode 8 min REMAINS PRIME P4 PUMP SPEED 85 End of prime Operate according to active mode with flow set for this mode and for preset time After Prime Mode is completed the pump will opera...

Страница 13: ...from the control After the pump has primed the Flow and Time Up Dn buttons as well as the 1 6 buttons are active Pressing any of the 1 6 buttons will cause the pump to run temporarily according to the...

Страница 14: ...ons and terminals are properly attached and connected E6 VFD EEPROM ER indicates that internal Emerson EEPROM memory is corrupted In such case the Emerson drive will not hold its predefined configurat...

Страница 15: ...Y HAYWARD GENUINE REPLACEMENT PARTS PRODUCT REGISTRATION Retain For Your Records DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODE...

Страница 16: ...be returned transportation paid to the place of purchase or to the nearest authorized Hayward service center For further Hayward dealer or service center information contact Hayward customer service d...

Отзывы: