TriStar Pump Series Page 6 of 8
™
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
WARNING
-
All wiring must be done by a licensed electrician.
Electrical (cont’d.)
Voltage
Voltage at motor
MUST NOT
be more than 10% above or below motor name place rated voltage, or motor may overheat, causing overload tripping
and reduced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power
company.
Grounding and Bonding
Install, ground, bond, and wire motor is accordance with local or Canadian Electrical Code requirements.
Permanently ground motor. Use green ground terminal provided under motor canopy or access place; use size and type wire required by code. Connect
motor ground terminal to electrical service ground.
Bond motor to pool structure. Bonding will connect all metal parts within and around the pool with a continuous wire. Bonding reduces the risk of a
current passing between bonded metal objects, which could potentially cause electrical shock if grounded or shorted.
Reference Canadian Electrical
Codes for all wiring standards including, but not limited to, grounding, bonding and general wiring procedures.
Use a solid copper conductor, size 6 or larger. Run wire from external bonding lug to reinforcing rod or mesh. Connect a No. 6 AWG solid copper
bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all
electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub.
Wiring
Pump MUST be permanently connected to circuit. If other lights or appliances are also on the same circuit, be sure to add their amp loads before
calculating wire and circuit breaker sizes. Use the load circuit breaker as the Master On-Off switch,
Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-circuit to ground and disconnect power before it becomes dangerous
to pool users. For size of GFCI required and test procedures for GFCI, see manufacture’s instructions. In case of a power outage, check GFCI for
tripping, which will prevent normal pump operation. Reset if necessary.
3 Phase Motor Specifications
Model #
Motor Break
HorsePower
HP (kW)
Motor Rated
Horsepower
HP (kW)
Service
Factor
Motor Electric
V/A
PH
Voltage
Amps
HCP3205C
1.0 (0.75)
0.5 (0.37)
2.0
575
1.15
3
HCP3207C
1.39 (1.04)
0.75 (0.56)
1.85
575
1.8
3
HCP3210C
1.9 (1.42)
1 (0.75)
1.9
575
2
3
HCP3215C
2.4 (1.79)
1.5 (1.12)
1.6
575
2.9
3
HCP3220C
2.8 (2.09)
2 (1.49)
1.4
575
3.1
3
HCP3230C
3.6 (2.68)
3 (2.24)
1.2
575
4.2
3
HCP3250C
5 (3.73)
5 (3.73)
1.0
575
5.2
3
575V
, 3Ph
Model #
Motor Break HorsePower Motor Rated Horsepower
Service Factor
Motor Electric V/A
PH
HP ( kW)
HP (kW)
Voltage
Amps
HCP320563
1.0 ( 0.75)
0.5 (0.37)
1.98
208-230/460
3.8-3.6/1.8
3
HCP320763
1.39 ( 1.04)
0.75 (0.56)
1.85
208-230/460
5.0-4.6/2.3
3
HCP321063
1.9 ( 1.42)
1 (0.75)
1.9
208-230/460
6.4-5.8/2.9
3
HCP321563
2.4 ( 1.79)
1.5 ( 1.12)
1.6
208-230/460
6.8-7.0/3.5
3
HCP322063
2.8 ( 2.09)
2 ( 1.49)
1.35
208-230/460
8.0-8.4/4.2
3
HCP323063
3.6 ( 2.68)
3 ( 2.24)
1.2
208-230/460
10.8-11.4/5.7
3
HCP325063
5 ( 3.73)
5 ( 3.73)
1.0
208-230/460
13.4-13.4/6.7
3
20
8-
23
0/
46
0
V, 3PH