background image

TriStar   Pump Series                                                                                                                       Page 2 of 8

WARNING -- 

This product should be installed and serviced only by a qualified professional.

CAUTION -- 

A Licensed electrician MUST complete, in full, all electrical installations noted in this manual.

Use of non-Hayward replacement parts voids warranty.

ATTENTION INSTALLER - THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION, 

OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT. 

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY.

    

WARNING - Read and follow all instructions in this 

owner’s manual and on the equipment. Failure to follow 

instructions can cause severe injury and/or death.

IMPORTANT SAFETY INSTRUCTIONS

Before installing or servicing this electrical equipment, turn power supply 

OFF

.

Basic safety percautions should always be followed, including the following: Failure to follow instructions may result in injury.

       This is the safety-alert symbol. When you see this symbol on your pump or in this manual, look for one of the following 

signal words and be alert to the potential for personal injury.

    DANGER

 warns about hazards that 

will

 cause serious potential injury, death or major property damage and if 

ignored presents an imminent hazard.

    WARNING

 warns about hazards that 

could

 cause serious personal injury, death or major property damage and if 

ignored presents a potential hazard.

    CAUTION

 warns about hazards that 

will

 or 

can

 cause minor or moderate personal injury and/or property damage 

and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe.

The 

NOTICE

 label indicated special instructions that are important but not related to hazards.

    

WARNING

 - To reduce risk of injury, do not permit children to use or climb on this product. Closely supervise 

children at all times. Components such as the filtration system, pumps, and heaters must be positioned to prevent children 

from using them as means of access to the pool.

    

CAUTION

 - This pump is intended for use on permanently installed swimming pools and may also be used with 

hot tubs and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in or on the 

ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is 

capable of being readily disassembled for storage and reassembled to its original integrity. Though this product is designed for 

outdoor use, it is strongly advised to protect the electrical components from the weather. Select a well-drained area, one that 

will not flood when it rains. It requires free circulation of air for cooling. Do not install in a damp or non-ventilated location. If 

installed within an outer enclosure or beneath a skirt of a hot tub or spa, adequate ventilation and free circulation of air must 

be provided to prevent overheating of the motor.

    

WARNING

 - Pool and spa components have a finite life. All components should be inspected frequently and 

replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached. 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Содержание TriStar Series

Страница 1: ...pendable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service calls read t...

Страница 2: ...or property damage and if ignored presents a potential hazard It can also make consumers aware of actions that are unpredictable and unsafe The NOTICE label indicated special instructions that are im...

Страница 3: ...aged broken cracked missing or unsecured cause sever injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cover Limb Entrapment A lim...

Страница 4: ...r clean Pump motors require free circulation from air for cooling Pump Mounting Install pump on a firm level base or pad to meet all local and national codes Fasten pump to base or pad with screws or...

Страница 5: ...tor can cause serious or fatal electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electri...

Страница 6: ...xcept gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring Pump MUST be permanently connected to circuit If other lights or appliances are also on the same c...

Страница 7: ...DLS SPX3200S SPX3200M SPX3200Z8 SPX4000Z1 SPX3200B3 SPX3200Z1 SPX3021R Description Union Connector Kit Nut Connector Gasket Union Gasket T seal 50 duro EPDM Pump Strainer Housing 2 x 2 with Drain Plug...

Страница 8: ...19 20 21 22 Part No SPX3207C SPX3210C SPX3215C SPX3220C SPX3230C SPX3200SA SPX3200T SPX3200E SPX3200Z211 SPX3200Z3 SPX3200Z5 SPX4000FG SPX3200GA SPX3200WF SPX3200SR Description Impeller for HP with I...

Отзывы: