background image

TriStar   Pump Series                                                                                                                       Page 5 of 8

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

    WARNING

 - 

Hazardous Pressure.

 Pumps, filters, and other equipment/components of a swimming pool 

filtration system operate under pressure. Incorrectly installed and/or improperly tested filtration equipment and/or components 

may fail resulting in injury and/or property damage.

Pump Mounting (cont’d.)

Plumbing

Use Teflon tape to seal threaded connections on molded plastic components. All plastic fittings must be new or thoroughly cleaned before 

use. 

NOTE - Do NOT use Plumber’s Pipe Dope as it may cause cracking to the plastic components.

 When applying Teflon tape to 

plastic threads, wrap the entire threaded portion of the male fitting with one to two layers of tape. Wind the tape clockwise as you face the 

open end of the fitting, beginning at the end of the fitting. The pump suction and outlet ports have molded-in thread stops. Do NOT attempt 

to force hose connector fitting past this stop. It is only necessary to tighten fittings enough to prevent leakage. Tighten fitting by hand and 

then use a tool to engage fitting an additional 1 ½ turns. Use care when using Teflon tape as friction is reduced considerable; 

do NOT 

over-tighten fitting or you may cause damage.

 If leaks occur, remove connector, clean off old Teflon tape, re-wrap with one or two 

additional layers of Teflon tape, and re-install connector.

Fittings

Fittings restrict flow. For better efficiency, use the fewest possible fittings (but at least two suction outlets). Avoid fittings that could cause 

an air trap. Pool and spa fittings MUST conform to the International Association of Plumping and Mechanical Officials (IAPMO) 

standards. Use a non-entrapping suction fitting in pool (multiple drains) or double suction (skimmer and main drain).

Electrical

    WARNING

 - 

Ground and bond motor before connecting to electrical power supply. Failure to ground and 

bond pump motor can cause serious or fatal electrical shock hazard.

    WARNING

 - 

Do NOT ground to a gas supply line.

    WARNING

 - 

To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on 

electrical connections.

    WARNING

 - 

Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical problem. If GFCI trips and 

wont reset, consult electrician to inspect and repair electrical system.

    WARNING

 - 

Fire Hazard.

 Match supply voltage to motor nameplate voltage.

Insure that the electrical supply available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the H.P. 

(KW) rating and distance from the power source. 

NOTE - All electrical wiring MUST be performed by a licensed electrician, and 

MUST conform to local codes and Canadian Electrical Code regulations.

 Use copper conductors only. 

Motor Specifications

 

M otor  B r ake H or sepower

 

M otor  Rated H or sepower

 

M otor  E lectr ic V /A

 

W ir e Size / B r eaker

 

H P  (kW )

 

H P  (kW )

 

V oltage

 

Amps

 

AW G

 

Amps

 

1.13  (0.84) 

0.50  (0.37) 

208 - 230 / 115 

5.3 - 4.9 / 9.8 

14 

10 / 15 

1.39  (1.04) 

0.75  (0.56) 

208 - 230 / 115 

7.0 - 6.2 / 12.4 

14 

10 / 15 

1.85  (1.38) 

1.00  (0.75) 

208 - 230 / 115 

8.5 - 7.4 / 14.8 

14 / 12 

15 / 20 

2.40  (1.79) 

1.50  (1.12) 

208 - 230 / 115 

11.2 - 10.2 / 20.4 

14 / 10 

15 / 30 

2.70  (2.01) 

2.00  (1.49) 

208 - 230 

11.8 - 11.0 

14 

15 

3.60  (2.69) 

3.00  (2.24) 

208 - 230 

16.0 - 14.8 

12 

20 

3.60  (2.69) * 

3.00  (2.24) * 

208 - 230 / 460 * 

9.6 - 9.4 / 4.7 * 

14 * 

15 / 10 * 

1.85 / 0.22  (1.38 / 0.16) 

1.00 / 0.12  (0.75 / 0.09) 

208 - 230 

8.6 - 8.2 ¹ 

14 

15 

2.40 / 0.28  (1.79 / 0.21) 

1.50 / 0.18  (1.12 / 0.13) 

208 - 230 

11.4 - 10.4 ² 

14 

15 

Fu

ll 

R

at

e P

um

ps

 

2.70 / 0.33  (2.01 / 0.25) 

2.00 / 0.25  (1.49 / 0.19) 

208 - 230 

12.4 - 11.2 ³ 

14 

15 

0.94  (0.70) 

0.75  (0.56) 

 

5.4 / 10.8 

14 

10 / 15 

1.25  (0.93) 

1.00  (0.75) 

230 / 115 

7.0 / 14.0 

14 

10 / 15 

1.65  (1.23) 

1.50  (1.12) 

230 / 115 

7.7 / 15.4 

14 / 12 

10 / 20 

2.20  (1.64) 

2.00  (1.49) 

230 / 115 

10.8 / 21.6 

14 / 10 

15 / 30 

2.60  (1.94) 

2.50  (1.86) 

230 

11.5 

14 

15 

3.45  (2.57) 

3.00  (2.24) 

230 

13.5 

14 

15 

1.85 / 0.22  (1.38 / 0.16) 

1.50 / 0.18  (1.12 / 0.13) 

208 - 230 

8.6 - 8.2 ¹ 

14 

15 

2.40 / 0.28  (1.79 / 0.21) 

2.00 / 0.25  (1.49 / 0.19) 

208 - 230 

11.4 - 10.4 ² 

14 

15 

M

ax

 R

at

e P

um

ps

 

2.70 / 0.33  (2.01 / 0.25) 

2.50 / 0.31  (1.86 / 0.23) 

208 - 230 

12.4 - 11.2 ³ 

14 

15 

¹ ²

-

  - 

-

 

    

-

-

 

 

¹, ², ³  Low Speed Amps:  (¹ 2.8 - 3.0) (² 3.2 - 3.4) (³ 3.8 - 4.1)

*      Three-Phase (3Φ) Pump - motor starter required

Содержание TriStar Series

Страница 1: ...pendable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service calls read t...

Страница 2: ...or property damage and if ignored presents a potential hazard It can also make consumers aware of actions that are unpredictable and unsafe The NOTICE label indicated special instructions that are im...

Страница 3: ...aged broken cracked missing or unsecured cause sever injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cover Limb Entrapment A lim...

Страница 4: ...r clean Pump motors require free circulation from air for cooling Pump Mounting Install pump on a firm level base or pad to meet all local and national codes Fasten pump to base or pad with screws or...

Страница 5: ...tor can cause serious or fatal electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electri...

Страница 6: ...xcept gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring Pump MUST be permanently connected to circuit If other lights or appliances are also on the same c...

Страница 7: ...DLS SPX3200S SPX3200M SPX3200Z8 SPX4000Z1 SPX3200B3 SPX3200Z1 SPX3021R Description Union Connector Kit Nut Connector Gasket Union Gasket T seal 50 duro EPDM Pump Strainer Housing 2 x 2 with Drain Plug...

Страница 8: ...19 20 21 22 Part No SPX3207C SPX3210C SPX3215C SPX3220C SPX3230C SPX3200SA SPX3200T SPX3200E SPX3200Z211 SPX3200Z3 SPX3200Z5 SPX4000FG SPX3200GA SPX3200WF SPX3200SR Description Impeller for HP with I...

Отзывы: