background image

TriStar   Pump Series                                                                                                                       Page 3 of 8

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

      

WARNING

 - 

Risk of Electrical Shock. It is required that licensed electricians do all the 

electrical wiring.

 Hazardous voltage. Can shock, burn, or cause death. To reduce the risk of electrical shock, do 

NOT use an extension cord to connect unit to electric supply. Provide properly located outlet. All electrical wiring 

MUST be in conformance with applicable local and national codes and regulations. Before working on pump or 

motor, disconnect motor wiring.

    WARNING

 - 

To reduce the risk of electrical shock replace damaged cord immediately. Do NOT bury cord. Locate cord to 

prevent abuse from lawn mowers, hedge trimmers and other equipment.

    WARNING

 - 

Connect only to a grounding type receptacle protected by a Ground Fault Circuit Interrupter (GFCI).

 

Contact a licensed electrician if you cannot verify that the receptacle is protected by a GFCI.

    WARNING

 -

 Failure to bond pump to pool structure will increase risk of electrocution and could result in injury or death. To 

reduce the risk of electrical shock, see installation instructions and consult a professional electrician on how to bond pump. Also, contact a 

licensed electrician for information on local electrical codes for bonding requirements.

Use a solid copper conductor, size 6 or larger. Run continuous wire from external bonding lug to reinforcing rod or mesh. Connect a No. 6 

AWG solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, 

or hot tub, and to all the electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming 

pool, spa, or hot tub. 

IMPORTANT

 - Reference Canadian Electrical Codes for all wiring standards including, but not limited to grounding, 

bonding and other general wiring procedures.

    WARNING

 - 

Suction Entrapment Hazard.

Suction in suction outlets and/or suction outlet covers which are damaged, broken, cracked, missing, or 

unsecured cause sever injury and/or death due to the following entrapment hazards:

Hair Entrapment 

- Hair can become entangled in suction outlet cover.

Limb Entrapment

 - A limb inserted into an opening of a section outlet sump or suction outlet cover that is 

damaged, broken, cracked, missing, or not securely attached can result in a medical bind or swelling of the 

limb.

Body Suction Entrapment

 - A differential pressure applied to a large portion of the body or limbs can result in an entrapment.

Evisceration/Disembowelment

 - A negative pressure applied directly to the intestines through an unprotected suction outlet 

sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in 

evisceration/disembowelment.

Mechanical Entrapment

 - There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be caught in 

an opening of a suction outlet cover resulting in mechanical entrapment.

    WARNING

 - 

To Reduce the risk of Entrapment Hazards:

- When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per 

pump must be installed. Suction outlets in the same place (i.e. floor or wall), must be installed a minimum of 

three feet (3’) [0.91 meter] apart, as measured from near point to near point.

- Dual suction fittings shall be placed in such locations and distanced to avoid “dual blockage” by a user.

- Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.

- The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found at the bottom of page 4 of this manual

- Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached.

- Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.

- In addition to two or more suction outlets per pump installed in accordance with the latest IAF (formerly NSPI) standards and CPSC 

guidelines, follow all national, state, and local codes applicable.

- Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.

Содержание TriStar Series

Страница 1: ...pendable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service calls read t...

Страница 2: ...or property damage and if ignored presents a potential hazard It can also make consumers aware of actions that are unpredictable and unsafe The NOTICE label indicated special instructions that are im...

Страница 3: ...aged broken cracked missing or unsecured cause sever injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cover Limb Entrapment A lim...

Страница 4: ...r clean Pump motors require free circulation from air for cooling Pump Mounting Install pump on a firm level base or pad to meet all local and national codes Fasten pump to base or pad with screws or...

Страница 5: ...tor can cause serious or fatal electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electri...

Страница 6: ...xcept gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring Pump MUST be permanently connected to circuit If other lights or appliances are also on the same c...

Страница 7: ...DLS SPX3200S SPX3200M SPX3200Z8 SPX4000Z1 SPX3200B3 SPX3200Z1 SPX3021R Description Union Connector Kit Nut Connector Gasket Union Gasket T seal 50 duro EPDM Pump Strainer Housing 2 x 2 with Drain Plug...

Страница 8: ...19 20 21 22 Part No SPX3207C SPX3210C SPX3215C SPX3220C SPX3230C SPX3200SA SPX3200T SPX3200E SPX3200Z211 SPX3200Z3 SPX3200Z5 SPX4000FG SPX3200GA SPX3200WF SPX3200SR Description Impeller for HP with I...

Отзывы: