8
Pool Low Speed
50%
Adjust the desired low speed for variable speed operation
Move to previous/next menu item
This setting will appear if “spa only” is not selected and variable speed filter pump is enabled. This
setting determines the speed of the pump during low speed pool or spillover operation. This value
can be set from “Lowest Speed” to 50% in 5% increments. 50% is default.
Set Day and Time
Wednesday 10:37P
Adjust the current day of the week
Move to hours setting
Set Day and Time
10:37P
Set Day and Time
Wednesday 37
Set Day and Time
Wednesday 10: P
Adjust the current hour (including AM/PM if applicable)
Adjust the current minute
Move to minutes setting
Move to previous/next menu item
Use this function to set the current day of the week and time. These values are used for all the
automatic timeclock functions of the OnCommand and are also displayed as part of the default menu.
The OnCommand is designed to keep the clock running during power outages lasting less than 7
days. If power has been off for longer than 7 days, then the time may have to be reset.
Display Light
On for 60 sec
Toggle between Always On and On for 60 sec.
Move to previous/next menu item
This function controls the backlight on the display. If the “60 seconds” option is selected, then the
backlight will automatically turn off 60 seconds after the last key is pressed and will stay off until next
time a key is pressed.
Note that the Display Light selection only applies to the display keypad that you are currently using.
Other display/keypads will not be affected. In other words, you need to individually set this option
for each display/keypad in the system.
Beeper
Enabled
Toggle between Enabled (default) and Disabled Beeper
Move to next menu item
When “Enabled”, the keypad will beep every time a key is pressed. If this audible indication is not
desired, select “Disabled”.
This function only applies to the display/keypad that you are currently using. You need to set this
option for each display/keypad in your system.
NOTE: This function is not supported on all display/keypads. If the “Enabled” selection is not
blinking, then the current software revision of that particular keypad/display does not support the
option and it will default to Beeper Enabled.
19
Lights Interlock
If enabled, this feature will override the function (Manual On/Off, Countdown Timer, Timeclock)
selected above and turn the lights relay off when: filter pump is off, first 3 minutes of filter pump
operation (allows the pump to prime and get water flowing), when the pool/spa suction return valves
are in any position other than “pool only”, or for the first 3 minutes after solar turns on (allows air in
the solar panels to be purged). Interlock is not available for solar, low speed filter pump, super
chlorinate, dimmer or group.
Lights Group
The Lights Group function allows the user to perform multiple tasks with a single push of the “Lights”
button. When setting up a Group function, refer to page 12 for specific programming information.
There are two Group menus; the first menu determines how the group command will be initiated
(Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions
and their respective control parameters.
Lights Freeze Protection
This function helps protect equipment that is wired to the lights relay against freeze damage. If Freeze
Protection is enabled and the AIR temperature sensor falls below the selected freeze temperature
threshold, the OnCommand will energize the lights relay. IMPORTANT: this only enables operation
of the lights relay during freeze--see the “Filter Pump Config.” menu to enable freeze protection for the
main circulation system.
Lights Pump Speed
This is the speed of the pump when the Lights output is on. The choices are the Settings Menu speed
and a speed that is unique to the Lights output only. The default selection is “Settings Menu”. This
is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an
alternate speed is desired when the Lights output is on, push “+” or “-” and select from “Lowest” to
“Highest” in 5% increments.
NOTE: The configuration parameters for the Aux2 output are the same as shown below for Aux1.
Aux1 Pump Spd
Settings Menu
Select between Settings Menu (default) and the desired pump speed
only if filter pump is set to variable
and relay type is set to standard
Move to previous/next configuration menu
Aux1 Config.
+ to view/change
Aux1 Function
Manual On/Off
Aux1 Relay
Standard
Push to access Aux options
Toggle between Standard (default) and Dimmer
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Aux1 Interlock
Disable
Aux1 Freeze
Disable
Toggle between Enabled and Disabled (default) Aux1 Interlock
T
oggle between Enabled
and Disabled Aux1 Freeze
(default)
Move to next menu item
Move to previous/next configuration menu
for manual on/off, countdown
timer and timeclock functions
Move to next menu item
Rotates between
Manual On/Off (default), Countdown Timer,
Low Speed- Filter, Timeclock, Solar, and Super Chlorinate
for all functions except dimmer relay, solar
super chlorinate, and low speed
f
super chlorinate, and low speed
or all functions except dimmer relay,
Aux1 Group
Filter: Unaffected
Aux1 Group
Timer: None(Manual)
Options available depend on the function that is selected
Rotates between Manual On/Off (default),Countdown Timer and Timeclock
Move to previous/next menu item or next configuration menu
Move to next menu item
for group function only
for group function only
!
WARNING: Do not use the OnCommand to control an automatic pool cover. Swim-
mers may become entrapped underneath the cover.
Aux1 Function
Manual On/Off (default)
—the aux relay will alternate between turning on and off when the aux button
is pressed. There is no automatic control logic.