11
This menu will appear only if the Lights are configured for timeclock. The lights will turn on and off at
the designated times. The only override on this function is manual on/off control by the “Lights”
button.
This menu will appear only if the Lights are configured for countdown timer. This setting is the time
after you manually turn on the lights until the OnCommand automatically turns off the lights. You can
also manually turn off the lights at an earlier time by pressing the LIGHTS button. If the Lights relay
is on during the programmed off time, it may be because of freeze protection.
Aux1 and Aux2 configurations are identical.
This menu will appear only if the Aux1 is configured for timeclock. The Aux output will turn on and off
at the designated times. If the Aux relay is off during the programmed on time— note that some pool
equipment (example pressure side pool cleaner) can only be operated when the filter pump is running
and the pool/spa valves are in the pool-only position—the OnCommand will keep the relay off until
these other conditions are suitable for operation. If the Aux relay is on during the programmed off
time, it may be because of freeze protection. Also, manual operation overrides the timeclock.
This menu will appear only if the Aux1 is configured for countdown timer. This setting is the time after
you manually turn on the Aux relay until the OnCommand automatically turns off the relay. You can
also manually turn off the relay at an earlier time by pressing the AUX1 button.
This menu will appear only if Valve3 is configured for timeclock. The valve will rotate on and off at the
designated times. There is no manual override. If the Valve3 relay is on during the programmed off
time, it may be because of freeze protection.
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Lights-all
8:00P to 11:00P
Lights-wkend
8:00P to 11:00P
Lights-wkday
8:00P to 11:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
or
Lights-CountDn
0:20
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:015...)
Move to previous/next menu item
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Aux1-all
8:30A to 4:00P
Aux1-wkend
8:30A to 4:00P
Aux1-wkday
8:30A to 4:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
or
Aux1-CountDn
0:20
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15...)
Move to previous/next menu item
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Valve3-all
8:30A to 4:00P
Adjust time s
Valve3-wkend
8:30A to 4:00P
Valve3-wkday
8:30A to 4:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
16
Heater Config.
+ to view/change
Heater
Disable
Heater Cooldown
Disabled
Heater Extend
Disabled
Push to access heater options
Toggle between Enabled and Disabled (default) Heater
Toggle between Enabled and Disabled (default) Heater Cooldown
Toggle between Enabled and Disabled (default) Heater Extend
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Heater1” is enabled
if “Heater1” is enabled
Allow Low Speed
Disabled
Toggle between Enabled and Disabled (default)
Move to next menu item or previous/next configuration menu
if “Heater1” is enabled and
1-speed filter pump is not selected
Heater
If the heater is “Enabled”, the heater relay will turn on when the water temperature is less than the
desired temperature setting and the filter pump is running. The desired temperature is in the “Settings
Menu”. If applicable, the homeowner will be prompted to enter separate “pool” and “spa” settings.
Depending on the position of the pool/spa suction valve, the proper temperature setting will be used.
Heater Cooldown
This feature ensures that the heater cools down before water circulation is stopped. When enabled,
the OnCommand will continue to run the filter pump for 5 minutes after the heater turns off. During
this period the filter pump LED will flash and also a “Heater Cooldown, X:XX remaining” message will
scroll on the display.
When the filter pump is running and the heater is on: Pressing the “Filter” button once will cause the
heater to turn off, but the filter pump will continue to run for heater cooldown (filter LED flashing and
message on display). Pushing the filter button a second time will override the heater cooldown
operation and turn the filter pump off.
Heater Extend
If “Enabled”, the filter extend logic keeps the filter pump running beyond the normal turn-off time until
the pool (or spa) is heated up to the desired temperature setting (see Settings Menu). Heater extend
will NOT cause the filter pump to turn on, it will only delay the turn off time when the heater is
operating.
Allow Low Speed
This menu only appears if the filter is configured for 2-speed or variable speed operation. During
default operation, high speed mode is used whenever the heater is on. If Allow Low Speed is enabled,