background image

 

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Page 9 of 24 

Max-Flo VS Pump

 

IS2300VSP   Rev C 

 

4.3.

 

Pipe Sizing Chart 

MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE

 

Pipe Size 

in.  [mm]

 

Maximum Flow Rate 

GPM  [LPM]

 

Minimum Straight  Pipe 

Length “L”  in. [mm] * 

1 ½”  [50] 

45  [170] 

7 ½”  [190] 

2”  [63] 

80  [300] 

10”  [254] 

2 ½”  [75] 

110  [415] 

12 ½”  [317] 

3”  [90] 

160  [600] 

15”  [381] 

 

* Note:

  It is recommended that a minimum length of straight piping (shown as “L” in above diagram), equivalent to 

5 pipe size diameters, be used between the pump suction inlet and any plumbing fittings (elbows, valves, etc.). 

When installing the Max-Flo VS, care should be taken to ensure proper pipe and equipment sizing to handle the 
maximum flow required. It is recommended to set the maximum speed in order to not exceed the maximum flow 
rate. See note at end of section 6.6. 

 

WARNING

 

– Hazardous Pressure

.  Pumps, filters, and other equipment/ components of a swimming pool 

filtration system operate under pressure.  Incorrectly installed and/or improperly tested filtration equipment and/or 
components may fail resulting in severe personal injury or death. 

4.4.

 

Plumbing 

1.

 

Use Teflon tape to seal threaded connections on molded plastic components.  All plastic fittings must be new or 
thoroughly cleaned before use.  NOTE - Do NOT use Plumber’s Pipe Dope as it may cause cracking of the plastic 
components.  When applying Teflon tape to plastic threads, wrap the entire threaded portion of the male fitting 
with one to two layers of tape.  Wind the tape clockwise as you face the open end of the fitting, beginning at the 
end of the fitting.  The pump suction and outlet ports have molded-in thread stops.  Do NOT attempt to force 
hose connector fitting past this stop.  It is only necessary to tighten fittings enough to prevent leakage.  Tighten 
fitting by hand and then use a tool to engage fitting an additional 1 ½ turns.  Use care when using Teflon tape as 
friction is reduced considerably; do NOT over-tighten fitting or you may cause damage.  If leaks occur, remove 
connector, clean off old Teflon tape, re-wrap with one to two additional layers of Teflon tape, and re-install 
connector. 

2.

 

Fittings (elbows, tees, valves, etc.) restrict flow.  For better efficiency, use the fewest possible fittings.  Avoid 
fittings that could cause an air trap.  Pool and spa fittings MUST conform to the International Association of 
Plumbing and Mechanical Officials (IAPMO) standards. 

4.5.

 

Electrical 

 

WARNING

 – All electrical wiring MUST conform to local codes, regulations, and the National Electric Code 

(NEC). 

 

WARNING

 – Ground and bond pump before connecting to electrical power supply.  Failure to ground and 

bond pump can cause serious or fatal electrical shock hazard.  Do NOT ground to a gas supply line.  To avoid 
dangerous or fatal electrical shock, turn OFF power to pump before working on electrical connections.  Fire Hazard - 
match supply voltage to pump nameplate voltage.  Insure that the electrical supply available agrees with the pump’s 
voltage, phase, and cycle, and that the wire size is adequate for the amps rating and distance from the power 
source.  Use copper conductors only. 

Содержание Max-Flo VS SP2300VSP

Страница 1: ...ilters heaters and pool cleaning equipment The totally enclosed permanent magnet motor combined with its advanced hydraulic design provides unparalleled energy savings Max Flo VS is designed for pools...

Страница 2: ...11 5 1 Input Power Wiring 11 6 Startup Operation 11 6 1 Prior to Start Up 11 6 2 Starting Priming the Pump 11 6 3 User Interface Summary 12 6 4 Menu Outline 13 6 5 Initial startup 13 6 6 Configuration...

Страница 3: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 3 of 24 Max Flo VS Pump IS2300VSP Rev C 11 Troubleshooting 20 11 1 General Problems 20 11 2 Error Codes 22 12 Warranty 22 13 Product Registration 23...

Страница 4: ...Electric Code NEC USE OF NON HAYWARD REPLACEMENT PARTS VOIDS WARRANTY ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS VARIABLE SPE...

Страница 5: ...NING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a pr...

Страница 6: ...e in off position and filter manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not c...

Страница 7: ...mperatures below freezing without issue 2 3 Product Dimensions 3 Energy Efficiency Overview The energy consumed by a pool pump is measured in terms of Watts W or Kilowatts kW The Max Flo VS displays p...

Страница 8: ...erate the pump at higher speeds for the shorter periods of time needed to operate a heater water feature etc 4 Installation and Wiring WARNING This product should be installed and serviced only by a q...

Страница 9: ...layers of tape Wind the tape clockwise as you face the open end of the fitting beginning at the end of the fitting The pump suction and outlet ports have molded in thread stops Do NOT attempt to force...

Страница 10: ...urrent passing between bonded metal objects which could potentially cause electrical shock if grounded or shorted Reference NEC codes for all wiring standards including but not limited to grounding bo...

Страница 11: ...pressure test prior to initial use to ensure plumbing system is functioning properly then the following criteria should be maintained for this test 1 Have a professional perform this test 2 Ensure all...

Страница 12: ...TION Before removing strainer cover 1 STOP PUMP before proceeding 2 CLOSE VALVES in suction and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve See...

Страница 13: ...creen information when pressed If the DISP FUNC button is held for several seconds it will enter the controller into configuration mode The and arrow buttons are used to change parameters within confi...

Страница 14: ...rotating block to emphasize the pump is in prime mode Note When Pump has finished Priming the pump will start speed V3 and display RPM Speeds can be selected at this time to temporarily run the pump h...

Страница 15: ...ttings excluding the current screen settings and exit configuration mode Note The maximum allow speed for speeds V1 through V3 is 3 000 RPM The minimum allowable speed for V1 through V3 is 600 RPM The...

Страница 16: ...FLASH A list of these error codes can be found in section 11 2 The cause of the internal error should be investigated and fixed before continuing to run the pump When the cause of the error has been f...

Страница 17: ...sed air can cause components to explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping ATTENTION...

Страница 18: ...the back of the pump 4 Remove the impeller by rotating counterclockwise 9 3 Removing the Ceramic Seat 5 Remove the spring seal assembly and seal plate from the motor by removing the four 4 3 8 x 1 bol...

Страница 19: ...gasket is in place and lubricated Replace if damaged Tighten bolts alternately and evenly to 185 inch pounds Looking at the back of the pump start with the top right move diagonal to the bottom left t...

Страница 20: ...bly includes parts 7 14 motor and drive 1 11 Troubleshooting 11 1 General Problems Motor Will NOT Start 1 Make sure the terminal board connections agree with the wiring diagram on the pump data plate...

Страница 21: ...s Check if all system hose clamps are tight ii Check voltage to ensure that the motor is rotating at full rpm s iii Open the housing cover and check for clogging or obstruction in suction Check the im...

Страница 22: ...f the error should be investigated and resolved before continuing normal operation of the pump When the issue has been resolved press the RUN STOP key to clear the error message Screen Buttons Used Co...

Страница 23: ...2300VSP Rev C DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING AT 3 000 RPM CLEAN FILTER _______________________ PUMP MODEL __________________ 13 Product Registration Retain th...

Страница 24: ...ll e mail communications regarding Hayward Equipment or promotions Mail to Hayward Pool Products 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept Or REGISTER YOUR WARRANTY ON LINE AT WWW HAYW...

Отзывы: