USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 14 of 24
Max-Flo VS Pump
IS2300VSP Rev C
Screen
Buttons
Used
Comments
.
DISP/FUNC
Display current Time Remaining
Cycles through to next screen
Time Display:
Hours . Minutes
DISP/FUNC
Display Current power usage in Watts
Cycles through to next screen
Note:
When in prime mode the priming duration and RPM screens are as below to separate prime mode from normal
operation.
.
When in Prime Mode the Prime mode
Timer will display timer remaining for
Prime Mode
Time Display:
Minutes . Seconds
DISP/FUNC
The RPM display for Prime mode
displays a rotating block to emphasize
the pump is in prime mode.
Note:
When Pump has finished Priming the pump will start speed V3 and display RPM.
Speeds can be selected at this time to temporarily run the pump, however, it is recommended that the drive
configuration and timers be set according to individual installation site requirements (see Section 11 for more
details). At this point, holding the DISP/FUNC button will enter into the Configuration Menu.
6.6.
Configuration Menu
Screen
Buttons
Used
Comments
DISP/FUNC
Press & Hold button for several
seconds to enter configuration mode
.
▲▼
DISP/FUNC
Adjust the time of prime mode
Move to the next selection
Note:
The prime mode timer can be adjusted up to 4 minutes and down to 0.00 minutes. When adjusted to 0.00
minutes, prime mode will be disabled.