background image

 

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Page 18 of 24 

Max-Flo VS Pump

 

IS2300VSP   Rev C 

9.

 

Shaft Seal Change Instructions 

IMPORTANT SAFETY INSTRUCTIONS 

PLEASE READ AND FOLLOW ALL INSTRUCTIONS 

When servicing electrical equipment, basic safety precautions should always be observed including the following.  
Failure to follow instructions may result in injury. 

 

 

WARNING

 – To reduce risk of injury, do not permit children to use this product. 

 

Disconnect all electrical power service to pump before beginning shaft seal replacement. 

 

Only qualified personnel should attempt rotary seal replacement.  Contact your local authorized Hayward Dealer or 
service center if you have any questions. 

Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal.  Foreign 
matter or improper handling will easily scratch the graphite and ceramic sealing surfaces. 

9.1.

 

Removing the Motor Assembly 

1.

 

Remove the four (4) 5/16" x1.75" hex head bolts, which hold the motor assembly to the pump/strainer housing, 
using a 1/2" wrench or socket. 

2.

 

Slide the motor assembly out of the pump/strainer housing, exposing the diffuser.  Remove the three(3) diffuser 
screws and pull the diffuser off the seal plate to expose the impeller. 

9.2.

 

Removing the Impeller 

3.

 

To prevent the motor shaft from turning, secure using a 6mm hex wrench on the motor shaft through the fan 
shroud on the back of the pump. 

4.

 

Remove the impeller by rotating counterclockwise.  

9.3.

 

Removing the Ceramic Seat 

5.

 

Remove the spring seal assembly and seal plate from the motor by removing the four (4) 3/8” x 1” bolts that 
secure it to the motor, using a 9/16" wrench or socket.   

6.

 

Press the ceramic seat with rubber cup out of the seal plate.  If tight, use a small screwdriver to tap seal out. 

STOP

 - Clean all recesses & parts to be reassembled.  Inspect gaskets & replace if necessary. 

9.4.

 

Seal Installation 

7.

 

Clean and lightly lubricate the motor shaft and seal recesses in the seal plate with a dilute solution of non-
granulated liquid-type soap. Gently wipe the polished face of the ceramic seal with a soft cotton cloth.  Lubricate 
the rubber cup on the ceramic seat and press it firmly into the recess of the seal plate, with the polished ceramic 
surface facing out. 

8.

 

Reassemble the motor to the seal plate using the four (4) 3/8” x 1” bolts. Torque the bolts to 100 in-lbs. 

9.

 

Gently wipe the black, polished surface of the spring seal assembly with a soft cotton cloth.   

10.

 

Press the spring seal assembly onto the motor shaft, with the black polished surface facing the ceramic seat. 

9.5.

 

Replacing the Impeller and Diffuser 

11.

 

Screw the impeller onto the motor shaft in a clockwise direction.  Tighten snugly by holding motor shaft with 
wrench as noted in step #3.   

12.

 

Place the diffuser over the impeller and onto the seal plate, aligning the three (3) protruding pins with the 
matching holes in the seal plate.  Note: Flat side of diffuser rim will face up.  Replace the three (3) diffuser 
screws, Torque screws to 20 in-lbs. 

Содержание Max-Flo VS SP2300VSP

Страница 1: ...ilters heaters and pool cleaning equipment The totally enclosed permanent magnet motor combined with its advanced hydraulic design provides unparalleled energy savings Max Flo VS is designed for pools...

Страница 2: ...11 5 1 Input Power Wiring 11 6 Startup Operation 11 6 1 Prior to Start Up 11 6 2 Starting Priming the Pump 11 6 3 User Interface Summary 12 6 4 Menu Outline 13 6 5 Initial startup 13 6 6 Configuration...

Страница 3: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 3 of 24 Max Flo VS Pump IS2300VSP Rev C 11 Troubleshooting 20 11 1 General Problems 20 11 2 Error Codes 22 12 Warranty 22 13 Product Registration 23...

Страница 4: ...Electric Code NEC USE OF NON HAYWARD REPLACEMENT PARTS VOIDS WARRANTY ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS VARIABLE SPE...

Страница 5: ...NING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a pr...

Страница 6: ...e in off position and filter manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not c...

Страница 7: ...mperatures below freezing without issue 2 3 Product Dimensions 3 Energy Efficiency Overview The energy consumed by a pool pump is measured in terms of Watts W or Kilowatts kW The Max Flo VS displays p...

Страница 8: ...erate the pump at higher speeds for the shorter periods of time needed to operate a heater water feature etc 4 Installation and Wiring WARNING This product should be installed and serviced only by a q...

Страница 9: ...layers of tape Wind the tape clockwise as you face the open end of the fitting beginning at the end of the fitting The pump suction and outlet ports have molded in thread stops Do NOT attempt to force...

Страница 10: ...urrent passing between bonded metal objects which could potentially cause electrical shock if grounded or shorted Reference NEC codes for all wiring standards including but not limited to grounding bo...

Страница 11: ...pressure test prior to initial use to ensure plumbing system is functioning properly then the following criteria should be maintained for this test 1 Have a professional perform this test 2 Ensure all...

Страница 12: ...TION Before removing strainer cover 1 STOP PUMP before proceeding 2 CLOSE VALVES in suction and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve See...

Страница 13: ...creen information when pressed If the DISP FUNC button is held for several seconds it will enter the controller into configuration mode The and arrow buttons are used to change parameters within confi...

Страница 14: ...rotating block to emphasize the pump is in prime mode Note When Pump has finished Priming the pump will start speed V3 and display RPM Speeds can be selected at this time to temporarily run the pump h...

Страница 15: ...ttings excluding the current screen settings and exit configuration mode Note The maximum allow speed for speeds V1 through V3 is 3 000 RPM The minimum allowable speed for V1 through V3 is 600 RPM The...

Страница 16: ...FLASH A list of these error codes can be found in section 11 2 The cause of the internal error should be investigated and fixed before continuing to run the pump When the cause of the error has been f...

Страница 17: ...sed air can cause components to explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping ATTENTION...

Страница 18: ...the back of the pump 4 Remove the impeller by rotating counterclockwise 9 3 Removing the Ceramic Seat 5 Remove the spring seal assembly and seal plate from the motor by removing the four 4 3 8 x 1 bol...

Страница 19: ...gasket is in place and lubricated Replace if damaged Tighten bolts alternately and evenly to 185 inch pounds Looking at the back of the pump start with the top right move diagonal to the bottom left t...

Страница 20: ...bly includes parts 7 14 motor and drive 1 11 Troubleshooting 11 1 General Problems Motor Will NOT Start 1 Make sure the terminal board connections agree with the wiring diagram on the pump data plate...

Страница 21: ...s Check if all system hose clamps are tight ii Check voltage to ensure that the motor is rotating at full rpm s iii Open the housing cover and check for clogging or obstruction in suction Check the im...

Страница 22: ...f the error should be investigated and resolved before continuing normal operation of the pump When the issue has been resolved press the RUN STOP key to clear the error message Screen Buttons Used Co...

Страница 23: ...2300VSP Rev C DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING AT 3 000 RPM CLEAN FILTER _______________________ PUMP MODEL __________________ 13 Product Registration Retain th...

Страница 24: ...ll e mail communications regarding Hayward Equipment or promotions Mail to Hayward Pool Products 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept Or REGISTER YOUR WARRANTY ON LINE AT WWW HAYW...

Отзывы: