USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
1-888-HAY-INDL (1-888-429-4635)
IS3200FC Rev A 5/13/2013
Pg. 7 of 14
www.haywardflowcontrol.com
Hayward Flow Control
Permanently ground motor. Use green ground terminal provided under motor canopy or access plate; use size and
type wire required by code. Connect motor ground terminal to electrical service ground.
Bond motor to system structure. Bonding will connect all metal parts within and around the system with a
continuous wire. Bonding reduces the risk of a current passing between bonded metal objects, which could
potentially cause electrical shock if grounded or shorted.
Reference NEC codes for all wiring standards
including, but not limited to, grounding, bonding and general wiring procedures.
Use a solid copper conductor, size 8 or larger. Run wire from external bonding lug to reinforcing rod or mesh.
Connect a No. 8 AWG (8.4 mm
2
) solid copper bonding wire to the pressure wire connector provided on the motor
housing and to all metal parts of system, and to all electrical equipment, metal piping (except gas piping), and
conduit within 5 ft. (1.5 m) of system.
Wiring
WARNING –
All electrical wiring MUST be in conformance with all applicable local codes, regulations,
and the National Electric Code (NEC).
Pump MUST be permanently connected to circuit. If other lights or appliances are also on the same circuit, be sure
to add their amp loads before calculating wire and circuit breaker sizes. Use the load circuit breaker as the Master
On-Off switch.
Motor Specifications
Motor Brake Horsepower
Motor Rated Horsepower
Motor Electric V/A
S
in
g
le
Ph
a
se
Pump
s
HP (kW)
HP (kW)
Voltage
Amps
0.99 (0.74)
0.50 (0.37)
208 - 230 / 115
5.3 - 4.9 / 9.8
1.39 (1.04)
0.75 (0.56)
208 - 230 / 115
7.0 - 6.2 / 12.4
1.85 (1.38)
1.00 (0.75)
208 - 230 / 115
8.5 - 7.4 / 14.8
2.40 (1.79)
1.50 (1.12)
208 - 230 / 115
11.2 - 10.2 / 20.4
2.70 (2.01)
2.00 (1.49)
208 - 230
11.8 - 11.0
3.60 (2.69)
3.00 (2.24)
208 - 230
16.0 - 14.8
5.00 (3.73)
5.00 (3.73)
208 - 230
21.0 - 19.4
T
h
re
e
Pha
se
Pump
s
0.99 (0.74)
0.50 (0.37)
208 - 230 / 460
3.1 - 3.0 / 1.5
1.39 (1.04)
0.75 (0.56)
208 - 230 / 460
4.0 - 3.8 / 1.9
1.85 (1.38)
1.00 (0.75)
208 - 230 / 460
5.5 - 5.0 / 2.5
2.40 (1.79)
1.50 (1.12)
208 - 230 / 460
6.9 - 6.2 / 3.1
2.70 (2.01)
2.00 (1.49)
208 - 230 / 460
7.8 - 7.0 / 3.5
Start-Up & Operation
Prior to Start-Up
NOTE
- If it is necessary to perform a pressure test, prior to initial use to ensure pump is functioning properly, then the
following criteria should be maintained for this test:
1.
Ensure all pump and system components are sealed properly to prevent leaks.
2.
Remove any trapped air in the system by fully opening filter manual air relief valve until a
steady stream of water (not air or air and water mix) is discharged from the valve.
3.
Allow no more than 50 psi (345 kPa) at a water temperature no higher than 100
F (38
C).
4.
Run pressure test for no longer than 24 hours. Immediately inspect all parts to verify they are
intact and functioning properly.