General Information
Introduction
This manual contains information for the proper installation and operation of the Hayward LifeStarTM Series Aquatic Pump.
The instructions in this manual
MUST
be followed precisely.
Failure to install according to defined instructions will void
warranty.
Product Specifications
Installation Instructions
WARNING
–
This product should be installed and serviced only by a qualified professional.
Pump Location
Locate pump as close to system as practical and run suction lines as direct as possible to reduce friction
loss. Suction lines should have continuous slope upward from lowest point in line. Joints must be tight
(but not over-tightened). Suction line diameter must equal or be larger than the discharge line diameter.
Though the pump is designed for outdoor use, it is strongly advised to place pump indoors, or in the
shade to shield them from continuous direct heat. Select a well-drained area that will not flood when it rains.
Do NOT
install pump and filter in a damp or non-ventilated location.
Keep motor clean. Pump motors require free circulation of
air for cooling.
Pump Mounting
Install pump on a level concrete slab or other rigid base to meet all local and national codes. Secure pump to base with
screws or bolts to further reduce vibration and stress on pipe or hose joints. The base must be level, rigid, and vibration free.
Pump mount must:
Allow pump inlet height to be as close to water level as possible.
Allow use of short, direct suction pipe (to reduce friction losses).
Allow for valves in suction and discharge piping.
Be protected from excess moisture and flooding.
Allow adequate access for servicing pump and piping.
HP
1 ph
3 ph
½
13 5/8”
13 13/16”
¾
13 7/8”
14 3/16
”
1
14 3/8”
14 11/16”
1 ½
14 7/8”
15 5/16”
2
14 7/8”
15 5/8”
3
17 1/8”
--
5
17 1/8”
--