![Hayward EcoStar SP3400VSP Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/hayward/ecostar-sp3400vsp/ecostar-sp3400vsp_owners-manual_2111075025.webp)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 25 of 32
EcoStar Variable Speed Pump
IS3400VSP Rev-B
Figure 8.6-1: Removing the Variable Speed Drive
Note: Motor leads must be disconnected prior to removing drive, and reconnected when new drive is mounted.
Take care to ensure that the motor leads are not pinched between the drive enclosure and the motor during
assembly. The drive mounting screws must be tightened to 30 inch-pounds.