EcoStar Variable Speed Pump
IS3400VSP Rev-B
3.12. Digital Control Interface Orientation
The Digital Control Interface can be rotated to any of four desired positions after installation by removing the two
screws securing the interface to the motor drive, lifting the interface and rotating it to the desired position, and
replacing the two screws in the new position. (Figure 3.12-1)
Figure 3.12-1
3.13. Interface Wall Mounting
The interface can also be wall mounted using the parts supplied in SP3200DRKIT using the following procedure.
1. TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER.
2. Remove the two screws securing the interface to the motor drive. (Figure 3.13-1)
3. Disconnect the short cable that extends out from the motor drive. (Figure 3.13-1)
4. Install the blank cover, SP3200DR9, on the motor drive in the desired orientation. This cover is important to protect
internal electronics. (Figure 3.13-2)
5. Mount the wall mount plate, SP3200DR10, in the desired location. (Figure 3.13-3)
6. Connect the interface cable as shown in the Wall Mounted Digital Control Interface Wiring diagram shown in section
4.2 to the motor drive and interface PCB. The cable must be routed through the “DATA” conduit opening on the
motor drive and through the slot provided on the backside of the wall mount plate, SP3200DR10. Cable used may be
up to 500 feet in length. (Figure 3.13-3)
7. Mount the interface to the wall mount plate, SP3200DR10, using the two screws. (Figure 3.13-3)
8. Apply power to the system and resume normal operation.
The following diagrams help illustrate the interface wall mounting procedure.