![Hayward EcoStar SP3400VSP Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/hayward/ecostar-sp3400vsp/ecostar-sp3400vsp_owners-manual_2111075022.webp)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 22 of 32
EcoStar Variable Speed Pump
IS3400VSP Rev-B
3.
Note: For SP3400VSPVR only, the SVRS feature is disabled during Quick Clean mode. When Quick Clean is pressed,
the above message is displayed to alert the user that SVRS is disabled, and that all bathers should exit the pool
during Quick Clean. If bathers are in the water, pr will return the pump to normal operation. If bathers are
not in the water, pressing – will allow the pump to run in Quick Clean mode, where it will run at the Max Allowed
Speed set in the Configuration Menu for 60 minutes. When Quick Clean is selected for SP3400VSP, the pump will
immediately proceed to Quick Clean mode.
4.
5.
6.
Note: The above message will be displayed while Quick Clean is running. For SP3400VSPVR, the check system light
will also flash on and off every two seconds as an additional reminder that SVRS is inactive. Quick Clean mode
expires after 60 min, and it may be cancelled early by pressing the Stop/Resume button, at which time the pump
would return to normal operation. For SP3400VSP, the SVRS Inactive message will not be shown, and the Check
System LED will not flash.
5.12. Remote Stop
Screen
1.
Note: The above message will be displayed when an installed remote stop switch is activated. The pump will
remain stopped until the remote stop switch is deactivated.
6. Maintenance
•
Clean strainer basket regularly. Do NOT strike basket to clean. Inspect strainer cover gasket regularly and replace as
necessary.
•
Hayward pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.
•
Keep motor clean. Insure motor air vents are free from obstruction to avoid damage. Do NOT use water to hose off
motor.
•
Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly
kit. See “Shaft Seal Change Instructions” in this manual.
7. Storage
/
Winterization
WARNING
– Separation Hazard. Do not purge the system with compressed air. Purging the system with
compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a
low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or piping.
Bathers in water?
+ = yes; - = no
SVRS Inactive
Quick Clean running
SVRS Inactive
Press resume to end.
SVRS Inactive
3200 rpm for 60 min;
Remote Stop
is engaged