IS3400VSP Rev-B
chosen for the pump. If the Relay Control is selected, the timer speed settings are invoked when inputs 1-3 (INP1-
INP3) are selected according to the following table:
Timer
Speed
INP1
Status
INP2
Status
INP3
Status
1 OFF
OFF
OFF
2 ON
OFF
OFF
3 OFF
ON
OFF
4 ON
ON
OFF
5 OFF
OFF
ON
6 OFF
ON
ON
7 ON
OFF
ON
8 ON
ON
ON
12.
+-
Use + to reset to factory default settings
<>
Use > to skip reset
13.
+-
Confirm reset of all parameters
<>
Move to next menu item
14.
5.7. Timer
Menu
Buttons
Screen
Used
Comments
1.
<>
Use > to enter Timer Menu
2.
3.
+-
Use + to change displayed timer
<>
Use > to skip to next timer
4.
+-
Use + to rename timer
<>
Use > to set motor speed for timer
5.
+-
Use to set speed for timer
<>
Use > to set start/stop time
6.
+-
Use to set start/stop time for timer
<>
Use > to choose days of operation for timer
Reset all parameters
+ for yes; > to skip
Timer Menu
Press > to enter
Timer 1
1725rpm
--- Off ---
Press + to change;
Press > next timer
T1: Timer 1
+/- rename; speed >
Timer 1
1725rpm
+/- adjust; times >
Timer 1
1725rpm
--- Off ---
Use Timers Menu to
set timeclocks.
Are you sure?
+ for yes; - for no