Page 19
Using the Goldline T-Cell Cleaning Stand
Follow the same safety and mixing instructions as described when using a container on page 14. Mix enough solution to fill the
inside of the cell ( Approximately 1.5 qts).
Mix 1 part acid to 4 parts water.
Fasten the cell to the T-Cell Cleaning Stand with the cord side down (Fig. 6A below). Before filling cell with muriatic acid solution,
put a container underneath to avoid any spills damaging the surrounding area. Fill the cell to the top with the solution and let
soak for 15 minutes (Fig. 6B below). Empty the cell and inspect. If the cell is clean, rinse with water and reinstall. If there are still
deposits after soaking, repeat the soaking procedure until clean. The water/muriatic acid mixture can be stored for later use or it
can be disposed of. Follow the chemical manufacturer’s recommendations when storing or disposing the water/acid solution.
After you inspect the cell (and clean, if necessary) press the small "diagnostic“ button next to the display for 3 seconds to stop the
flashing "Inspect Cell" LED and reset the countdown timer for another 500 operational hours. If the cell was cleaned because of
‘Low Salt’’, be sure to reset the average salt reading by following the instructions on page 6.
Cell Cleaning Instructions