Page 18
Cell Cleaning Instructions
We strongly recommend using a Goldline Controls cell cleaning stand. (GLX-CELLSTAND)
Step 1:
Use a water hose to dislodge small debris.
Step 2:
Use a solution of water and Muriatic acid. Stand the cell vertically in the solution. Mix 1 part acid to 4 parts water. The
level of the solution should be slightly over the product label. Let the cell stand in the solution for 15 minutes (Fig. 6A below), then
flip the cell over and let stand on the other end (Fig. 6B below) for an additional 15 minutes. Although the cord can be
submerged, be sure that the connector does not come in contact with the solution.
Inspect the cell after both sides have soaked. If there are no deposits after soaking, rinse with water and reinstall. If there are still
deposits after soaking, repeat the soaking procedure until clean. The water/muriatic acid mixture can be stored for later use or it
can be disposed. Follow chemical manufacturer’s recommendations when storing or disposing the water/acid solution.
After you inspect the cell (and clean, if necessary) press the small "diagnostic“ button next to the display for 3 seconds to stop
the flashing "Inspect Cell" LED and reset the countdown timer for another 500 operational hours.
Cleaning instructions
using a container
.