USE ONLY GENUINE REPLACEMENT PARTS
Page 17 of 21
Aq
Rev. B
7
Intelligent*:
In this mode, the user has two operating
parameters: Select the required water temperature
and the minimum filtration time (minimum two hours
and maximum 24 hours). The filtration will operate
for at least ten minutes every two hours to check the
temperature. The minimum filtration time selected is
divided into twelve sections that are added to its ten
minutes.
Example 1:
Over twelve hours, the time
is divided between the twelve times a day when the
filtration starts up to check the temperature.
Example 2:
(12 hours x 60 minutes) / 12 = 60 minutes
every two hours. This is the filtration and heating
period every two hours. If the programmed filtration
period ends and the required temperature has not
been reached, the filtration and heating remain on until
the required temperature is reached. To minimize the
number of hours during which filtration operates each
day, this additional time will be deducted from the next
filtration periods occurring during the rest of the day.
(See the chart below).
*
Note:
Modes visible only when the temperature
and / or heating probe use option is activated in the
INSTALLER menu
0h
10 min
1h
3h
5h
7h
9h
11h
13h
15h
17h
19h
21h
23h
2h
4h
6h
8h
10h
12h
14h
16h
18h
20h
22h
24h
T°= 28ºC
0h
10 min
1h
OFF
ON
3h
5h
7h
9h
11h
13h
15h
17h
19h
21h
23h
2h
4h
6h
8h
10h
12h
14h
16h
18h
20h
22h
24h
28ºC
28ºC
27ºC
27ºC
28ºC
Intelligent mode operation if the temperature is constant
Intelligent mode operation if the temperature varies
Intelligent mode
Lighting
1
2
3
OK
+
-
1
Lighting.
2
Manual mode
(ON/OFF)
.
3
Automatic mode:
Starts up according to the time slots used
to set the lighting start and end times. The time slots can
be configured with the following frequencies: daily, every 2
days, every 3 days, every 4 days, every 5 days, weekly, every
2 weeks, every 3 weeks, every 4 weeks.
Setting the pump type
1
2
3
4
5
6
OK
OK
OK
3
Enter
the Service menu from the configuration
menu
4
Enter
the password (contact Hayward's technical
support for the code)
5
Enter
the Pump type menu.
6
Select
the type of pump.