Installing the hydraulic system
Disconnect the pool filtration pump before starting the installation. The system must be installed in accordance with the standards
currently in force in the country of installation. The control box must be fitted a minimum horizontal distance of 3.5 m (or more, if
required by local regulations) from the pool, within 1.5 m of a protected outlet and 4.5 m of the planned cell location.
Mount the box and the measuring chamber on the wall. The box must be installed in the equipment room (dry, temperate,
ventilated). Caution, acid vapours can cause irreversible damage to your device. Position the treatment product tanks accordingly.
The flow switch must be installed on the return pipe directly in line with and upstream of the cell and the treatment product injection
point. Allow a 25 cm straight section before the flow switch. A hole should previously have been drilled in the pipe to allow the flow
switch to pass through. Screw the flow switch into the saddle clamp, taking care to seal with Teflon. Then install the clamp on the
pipe. The flow switch must be installed in the direction of operation to ensure that it is tripped by the flow from the filtration pump.
The device used to inject the treatment products (acid, etc.) must be installed last on the water return line, after any equipment
(heater, cell, etc.). A hole should previously have been drilled in the pipe to allow the treatment product to pass through. Install the
saddle clamp and screw the injection valve into the saddle clamp using the adapter provided. Seal with Teflon.
Use the transparent PVC hose for suction (between the acid tank and the peristaltic pump) and the semi-rigid white polyethylene
tube for injection (between the peristaltic pump and the injection valve).
All the metal components of the swimming pool can be connected to the same earth as per local regulations.
Temperature
probe
Pump
Filter
Heater
Flow
switch
Cell
POOL
From
pool
From
Spa
Back to
pool
Back to
Spa
ORP
probe
pH
probe
Acid