5.  Reinstall all 4 of the original screws.

 

 

a. Loosely tighten all four screws.

 

 

b. Then go back and firmly tighten each screw.

6.  The spaside remote will remember the ID code of the base station, so it is not necessary to 

perform the “Teach Wireless” procedure again. Verify proper operation by pressing any button 

and observing 2 flashes indicating that the message was transmitted to the base station and 

a confirmation was received.

Troubleshooting

1.  Can’t find the “Teach Wireless” display: 

 Press the “menu” button (possibly more than 

once) until “Settings Menu” is displayed. Next, press the “<“ or “>” buttons (possibly more 

than once) unit the “Teach Wireless” display appears. If you get to the point where “Settings 

Menu” appears again, then this means that the Pro Logic/Aqua Logic  control unit is not 

communicating with the base station. Check that the 4 wire cable from the base station is 

plugged into the “wireless" connector on the main printed circuit board. If this connector is 

already plugged in (for more than 30 seconds), then call Hayward Technical Service for as-

sistance.

2.  “Teach Wireless” failed:

  

Ensure that the remote is powered when pressing the button. This 

is indicated by a single flash of the LED on the spaside remote or a message on the display 

of the in-house remotes. If the remote is powered, then the next most likely cause is that the 

distance between the base station and the remote is too great—try moving the remote closer 

to the base station. Lastly, there may be other equipment in the neighborhood that is using 

the same frequency. To see if this is the case, go to the Settings Menu/Wireless Channel and 

select another channel. Note that after you change the channel you will have to “reteach” 

every wireless remote device in the system.

3.  Unreliable communication with remote devices:

  The most likely cause is that the dis-

tance between the base station and the remote is too great—try moving the remote closer 

to the base station. Lastly, there may be other equipment in the neighborhood that is using 

the same frequency. To see if this is the case, go to the Settings Menu/Wireless Channel and 

select another channel. Note that after you change the channel you will have to “reteach” 

every wireless remote device in the system.

4.  Single LED flash when a button is pushed: 

 The radio signal may be too weak—try point-

ing the spaside remote in the direction of the pool equipment or try moving closer to the pool 

equipment. If that doesn’t work, then try the “Teach Wireless” procedure to ensure that the 

remote knows the ID code of the base station and also what channel to communicate on. If 

this procedure is not successful, then refer to the “Teach Wireless” failed section above. 

5.  The filter pump won’t turn off when the "OFF" button is pressed: 

 (1) If the heater 

cooldown feature is enabled and the heater is on, then pressing the "OFF" button will cause 

the heater to turn off but leave the filter pump running for 5 more minutes to allow the heater 

to cooldown. Pressing the "OFF" button a 2nd time will override the cooldown period and turn 

the pump off. (2) If the freeze protection feature is enabled and the air temperature is less 

than 38°F then the pump will run continuously and any OFF button press will be disregarded.  

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

4

Содержание AQL2-SS-RF

Страница 1: ...abeth NJ 07207 Phone 908 355 7995 www hayward com Contents Installation 1 Operation 2 Troubleshooting 4 Warranty 6 Spaside Remote Control for Aqua Logic and Pro Logic Owner s Manual AQL2 SS RF USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 092152D RevB ...

Страница 2: ... base station installed The base station allows the Pro Logic Aqua Logic control unit to communicate with the spaside remote 3 Teach the unique ID code The base station attached to the Pro Logic Aqua Logic control unit has a unique ID code that ensures that your unit will not affect other systems in the neighborhood and likewise their remote will not affect your system To teach the ID code to the ...

Страница 3: ...mation that the command has been successfully transmitted to the control unit If the LED doesn t flash at all or else just flashes once after you ve pushed a button refer to the Troubleshooting section for assistance in resolving these problems Valves POOL SPA These buttons will allow you to select either pool or spa operation You can not select spa spillover operation from the spaside remote Filt...

Страница 4: ...l settings e g timeclock The manual setting will remain active until the next scheduled automatic turn on off event Note that the Aux3 Aux6 outputs on Pro Logic Aqua Logic PS 8 models Aux3 Aux14 on PS 16 mod els can NOT be controlled by this remote Battery Replacement The spaside remote runs on two AAA batteries Since the internal circuits are only active when you push a button it is anticipated t...

Страница 5: ...uency To see if this is the case go to the Settings Menu Wireless Channel and select another channel Note that after you change the channel you will have to reteach every wireless remote device in the system 3 Unreliable communication with remote devices The most likely cause is that the dis tance between the base station and the remote is too great try moving the remote closer to the base station...

Страница 6: ...the Pro Logic Aqua Logic system is in service mode then functions can only be turned on at the main unit display keypad Press the SERVICE button once or twice until normal operation is restored 3 The filter pump is turned off for a short period of time while the valves are rotating Normal operation will resume automatically when the valve s have finished their rotation 5 USE ONLY HAYWARD GENUINE R...

Страница 7: ...nformation on authorized service centers please contact the Hayward Technical Service Support Center 61 Whitecap Road North Kingstown RI 02852 or visit the Hayward web site at www hayward com WARRANTY EXCLUSIONS 1 Material supplied or workmanship performed by others in process of installation 2 Damage resulting from improper installation including installation on pools larger than the product rati...

Страница 8: ...ayward is a registered trademark and Aqua Logic and Pro Logic are trademarks of Hayward Industries Inc 2016 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not in any way affiliated with or endorsed by those third parties ...

Отзывы: