Hawk MiniWave Ultrasonic Level Series Скачать руководство пользователя страница 6

Installation

MiniWave

 

User Manual

6

Powering The Unit

When power is applied, the unit will start up automatically. The LCD will scroll through its boot diagnostics and 
display the serial numbers, software version and model types for the amplifier and transducer.

The selected Display Mode will be visible with a measurement. 

The top right hand corner diagnostic indicates either the operating mode or the current output.

The unit will re-scan for the level whenever it is powered up.

 185 mm (7.3”)

 

52mm 

(2”)

 72mm  (2.8”)

 47mm (1.85”)

2" BSP or 

NPT THD

 85mm (3.4”) 

M20

Cable 

Gland

M20 Blank Plug

+

-

23mm (0.9”)

+

-

CAL

RUN

Space

1.402m

17.2mA

m i n i   w a v e

Space

1.402m

17.2mA

Set Lo Level

Set Hi Level

AutoSet

SCANNING

Set Lo Level

No

Yes

       2.597m 

Set Lo Level

 185 mm (7.3”)

 

52mm 

(2”)

 72mm  (2.8”)

 47mm (1.85”)

2" BSP or 

NPT THD

 85mm (3.4”) 

M20

Cable 

Gland

M20 Blank Plug

+

-

23mm (0.9”)

Flip Lid

to access

terminals

+

-

CAL

RUN

Space

1.402m

17.2mA

M i n i W a v e

Space

1.402m

17.2mA

Set Lo Level

Set Hi Level

AutoSet

SCANNING

Set Lo Level

No

Yes

       2.597m 

Set Lo Level

Diagnostic

Display Mode

Interface

Button

Action

Navigation / Function

Press and release 

Press and hold for 3 seconds

Access Main Menu

Select / Proceed

Access AutoSet Menu

Press and release

Cancel / Return
Re-activate unit

Press and Release

Scroll between live diagnostics

Scroll between menu options

Adjust parameters

Main Menu

Setup

Advanced

Autoset

Setup

Display Mode

Display Unit

Low Level

Hi Level

Damping

FailSafe

Advanced

Comms

Echo Size

Lock Code

Analogue

Language

Autoset

See (B) Autoset

Main Menu

Setup

Advanced

Autoset

Setup

Display Mode

Display Unit

Low Level

Hi Level

Damping

FailSafe

Advanced

Comms

Echo Size

Lock Code

Analogue

Language

Autoset

See (B) Autoset

Main Menu

Setup

Advanced

Autoset

Setup

Display Mode

Display Unit

Low Level

Hi Level

Damping

FailSafe

Advanced

Comms

Echo Size

Lock Code

Analogue

Language

Autoset

See (B) Autoset

Содержание MiniWave Ultrasonic Level Series

Страница 1: ...MiniWave Ultrasonic Level Series Liquid Level Measurement User Manual Sultan Sonar Manual Rev 1 0 A Higher Level of Performance www hawkmeasure com For more information please visit...

Страница 2: ...Commissioning Software 7 Startup 7 Main Menu 7 Setup 7 AutoSet 7 Advanced Settings 8 HART 9 HART Universal Common Practice command list 9 Troubleshooting 10 Unit is displaying incorrect distance 10 An...

Страница 3: ...ndustries Principle of Operation The MiniWave emits an ultrasonic pulse which is reflected from the surface of the liquid being measured The reflected signal is processed using specially developed sof...

Страница 4: ...ring 15mm 0 60 2 NPT or BSPT INTERNAL THREAD 152mm 6 0 4 x 19mm 0 75 HOLES THROUGH 120mm 4 7 P C D FA2NB 4 2 ANSI Polypropylene Flange for NPT threaded units FA2BB 4 2 ANSI Polypropylene Flange for BS...

Страница 5: ...re of a curved roof to avoid the potential of parabolic echoes Ensure appropriate UV protection 2 NPT MWN1A or 2 BSPT MWB1A min 250mm 10 min 250mm 10 These are examples of common INCORRECT mountings w...

Страница 6: ...e Space 1 402m 17 2mA SCANNING Set Lo Level No Yes 2 597m Set Lo Level Diagnostic Display Mode Interface Button Action Navigation Function Press and release Press and hold for 3 seconds Access Main M...

Страница 7: ...toset See B Autoset Main Menu Setup Advanced Autoset Setup Display Mode Display Unit Low Level Hi Level Damping FailSafe Advanced Comms Echo Size Lock Code Analogue Language Autoset See B Aut AutoSet...

Страница 8: ...EchoSize The unit will target this echo size measured in signal voltage during operation High values can increase stability but make the unit more susceptible to false echoes Lower values can make th...

Страница 9: ...ident associated with tag 12 Read message 13 Read Tag Description Date 14 Read PV sensor information 15 Read output information 16 Read final assembly number 17 Write message 18 Write Tag Description...

Страница 10: ...ng with the transit pulse in the application such as ladders and cross beams Unit is locked up or flat line measurement Confirm there is material within measurement range the unit may go to Failsafe i...

Страница 11: ...cessories FA2NB 4 2 ANSI Polypropylene Flange for NPT threaded units FA2BB 4 2 ANSI Polypropylene Flange for BSPT threaded units Hawklink MiniUSB PC connecter for GoshawkII Model Type MWN1A MiniWave w...

Страница 12: ...t Resolution 1 mm 0 04 Electronic Accuracy 0 25 of maximum range Operating Temperature 40 C to 60 C 40 F to 140 F Maximum Operating Pressure 0 5 to 3 bar 0 44 PSI Automatic Temperature Compensation Ye...

Страница 13: ...Contact MiniWave User Manual 13 13 13...

Страница 14: ...Overview MiniWave User Manual 14 14...

Страница 15: ...Overview MiniWave User Manual 15 15...

Страница 16: ...he need for immediate technical assistance The HawkLink 3G communication device allows any computer with internet access and our free GosHawk diagnostic calibration software to dial in calibrate test...

Отзывы: