Vibration/impact
Vibrations, sinusoidal
DIN EN 60068-2-6
sine: 3 g, 5 to 100 Hz, 3x15 h per axis
Vibrations, broadband noise (digital
control) and guidelines
DIN EN 60068-2-64 broadband: 1.4 g, 5 to 200 Hz, 3x8 h per
axis
Vibrations
DIN EN 60068-2-29 Shock (impact) 30 g, 15000 x 6 ms
Shocks
DIN EN 60068-2-27 3 shocks at 5 g, 11 ms in each + and -
direction (18 shocks)
Minimum space require-
ments (LxWxH)
■
Tank size 1: 198 x 111 x 95 cm
■
Tank size 2: 223 x 111 x 95 cm
■
Tank size 3: 248 x 111 x 95 cm
10.1.2.1 Tank size
Coding
Fill volume (l)
Usable volume (l)
1
0.370
0.300
2
0.560
0.450
3
0.750
0.600
10.1.3 Electrical data
Rated voltage
12 to 24 V DC
Current consumption
see characteristic curves, max. 105 A at 12 V or 52.5 A at 24 V
Overload protection
Temperature switch (NTC)
Power
1500 W
Duty cycle
Continuous
operation:
S1 at 030 bar and 1.5 lpm
Intermittent
operation:
S3 at 060 bar and 2.0 lpm and 45% duty cycle
Intermittent
operation:
S3 at 080 bar and 1.5 lpm and 25% duty cycle
Intermittent
operation:
S3 at 150 bar and 1.0 lpm and 10% duty cycle
Protection class
IP 67 according to IEC 60529
Software control
CAN bus: Flow rate limit A and B side 0.5 to 3.0 lpm, separately to 0 to 100% open ow through A or B, when
running
Hardware control
two signal lines for 12 V or 24 V for ow through A or B
HAWE Hydraulik SE
B 8543 - 10-2021 - 1.0
25/27