1.7 PILOTE WIRE MODE
In the Pilote Wire mode, the high temperature (set locally into the comfort mode) is modified depending on the commands
received from the Pilot Wire control unit, except the case with Pilot wire not connected.
RCB recognizes 6 commands: comfort, reduction (high temperature -3.5°C), stop, antifreeze (7°C), eco1 (high temperature -1°C),
and eco2 (high temperature -2°C).
Push the FUNCTION button until you find this mode .The screen appears as in Figure:
The STOP command is enabled in all modes, except for the standby state.
If the STOP command was implemented outside of the mode Pilote Wire, the icon blinks.
With the STOP command present is still possible to put the RCB in stand-by state pushing the ON/Stand-by button .
The heater must not be installed just underneath a mains socket.
The heater must never be installed in a bathroom in a position in which the switches or other controls can be touched by a
person in the bath or shower.
The RCB heater operates by natural air convection. In order to achieve correct performance with uniform heat distribution,
when installed on a wall, the lower part of the heater must a minimum of 10 cm and a maximum of 30 cm from the floor.
There must be a minimum distance of 15 cm from any wall or object (furniture and curtains etc), both to the sides and
above, to ensure adequate heating performance.
WARNINGS
Brown
Phase
Blue or Grey
Neutral
Black
Pilot-wire or not connected
Wire colour connection
Symbol of FP command
recognized (see table)
Set-point
Pilote Wire icon
and
and
and
and
and
Pilote-Wire signal
Icons on the screen
Set-point value/ writting
COMFORT
REDUCTION
ECO1
ECO2
ANTIFREEZE
STOP
HIGH TEMPERATURE
HIGH TEMPERATURE - 3.5 ºC
HIGH TEMPERATURE - 1 ºC
HIGH TEMPERATURE - 2 ºC
7 ºC
STOP
2. INSTRUCTIONS FOR THE INSTALLATION