background image

6

Comfort from 05:00 to 10:00 h and from 17:00 to 23:00 h has selected comfort temperature and the economy

temperature in the other time slots. See the following picture:

If, during the time setting and weekly program, the ON/Stand-by button                is pressed, the RCB goes into stand-by 
state, saving the new timing/date while the new weekly program is not saved. 

With a new pressing on the ON/Stand-by button               , the RCB goes into ON state into the mode that was present 
before the time setting.

In case of 230Vac supply power cut off, the chrono weekly program, the high and low temperature are retained into the 
memory, instead the current time is lost. 

After the 230Vac power supply comes back, if one of the chrono modes is selected (chrono, P1, P2, P3), the symbol            
and the display writing flickers (the time or P1, P2, P3 depending on the mode selected): in that case following the 
procedure described at the beginning of the paragraph it is possible to set the time. 

Until the operation is not performed, RCB temporarily counts the time from the  moment when the power supply 230Vac 
has become available again (and this "temporary" time is used in case you selected one of the chrono mode).

RCB has the possibility to use the “classic” CHRONO Mode (to be setup by the user) and also three type of integrated 
programming modes, named P1, P2, and P3 respectively. 

To switch from one mode to the next mode push the FUNCTION button              until you find the desired mode.

The modes P1, P2 and P3 work as follow:

P1

Monday-Friday:  Comfort from 06:00 to 08:00 h and from 17:00 to 00:00 h

Saturday-Sunday: Comfort from 06:00 to 08:00 h, 12:00 to 14:00 h and from 17:00 to 00:00 h 

P2

Monday-Sunday:  Comfort from 17:00 to 00:00 h 

P3

Monday-Sunday:  Comfort from 08:00 to 20:00 h 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

+  + 

+  +  + 

COMFORT

COMFORT

 

FINAL

Pressing the buttons:

Comfort
or
Economy

1.6. INTEGRATED PROGRAMMING MODES

P1

P2

P3

Содержание RCB

Страница 1: ...Instructions and instalation manual RCB RCBV2_2016_MOOR ESPFUK2016 www haverland co uk CLASS II IP 24 ...

Страница 2: ...ual in order to ensure correct operation TABLE OF CONTENTS 0 General warnings Page 3 0 0 Safety warnings Page 3 1 Heater description Page 3 1 1 Keyboard and LCD display Page 3 1 2 Working description Page 4 1 3 Children s safety Page 5 1 4 Time setting and hourly programming Page 5 1 5 Programmation Function Chrono Page 5 1 6 Integrated programming modes Page 6 1 7 Pilote wire mode Page 7 2 Instru...

Страница 3: ...h external programming devices or any other device of exterior control EXCEPT Pilot Wire external devices The smoke from cigarettes candles and incense burners combined with the effect of convection can cause stains on the wall This is not a failure the apparatus Furthermore the effect of sunlight or halogen may cause some discolouration in the apparatus Temperature variations in the immediate envir...

Страница 4: ...re disabled Integrated preset weekly program P2 evening weekly program at two temperature levels high and low All the pilot wire commands except STOP are disabled Integrated preset weekly program P3 daytime weekly program at two temperature levels high and low All the pilot wire commands except STOP are disabled Temperature settings are at two different levels high and low High temperature is used ...

Страница 5: ...mperature Low temperature 1 4 TIME SETTING AND HOURLY PROGRAMMING 1 Hold down the ON standby and function buttons simultaneously for at least 3 seconds 2 The hour digits begin to flash Use and to set the current hour and confirm by pressing the function button 3 Set the minutes and day in the same way The day is marked by a dot on the vertical numbered scale 1 Monday CONTINUE 1 5 Programmation Funct...

Страница 6: ...n the mode selected in that case following the procedure described at the beginning of the paragraph it is possible to set the time Until the operation is not performed RCB temporarily counts the time from the moment when the power supply 230Vac has become available again and this temporary time is used in case you selected one of the chrono mode RCB has the possibility to use the classic CHRONO M...

Страница 7: ...ket The heater must never be installed in a bathroom in a position in which the switches or other controls can be touched by a person in the bath or shower The RCB heater operates by natural air convection In order to achieve correct performance with uniform heat distribution when installed on a wall the lower part of the heater must a minimum of 10 cm and a maximum of 30 cm from the floor There mu...

Страница 8: ...cted to the mains power supply Only you can to install the radiator in ZONE 3 DO NOT USE THIS HEATER IN THE IMMEDIATE OF A BATH A SHOWER OR A SWIMMING POOL zone 0 1 and zone 2 Marsan Industrial S A reserves the right to modify without previous warning RCB2_2016_MOOR ESPFRUK2016 We recommend that all parts of the radiator are kept clean behind underneath upper fins etc Dust it with a dry and soft cl...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ... Challenge House Sherwood Drive Bletchley MK3 6DP Customer Service Telephone 0330 3651940 Fax 01672 811944 Email haverland haverland co uk www haverland co uk RCB Made in Spain RC12B W 1200 12 Nº 230 V 50 Hz CLASS II IP24 ...

Отзывы: