COMFORT 

 

Unlimited time regulation for high temperature 

 

 

 

All the pilot wire commands except STOP are disabled

ECONOMY 

 

Unlimited time regulation for low temperature 

 

 

 

All the pilot wire commands except STOP are disabled

ANTIFREEZE 

 

Unlimited time regulation at 7°C

 

 

 

All the pilot wire commands except STOP are disabled  

CHRONO 

 

Shows weekly programme at two temperature levels (high and low) established by the user hour 

 

 

 

by hour. All the pilot wire commands except STOP are disabled 

 

FILOT-WIRE 

 

The high temperature (locally set in Comfort mode) is modified by the commands received from 

 

 

 

the pilot wire central control unit, except the case with the pilot wire not connected. RCB decodes 6 

 

 

 

commands: comfort, reduction (high temperature - 3.5°), stop, antifreeze (7°), eco 1 (high 

 

 

 

temperature - 1°) and eco 2 (high temperature - 2°)

INTEGRATED 

PROGRAM 
P1

INTEGRATED

PROGRAM
P2

INTEGRATED

PROGRAM
P3

   

 

4

1.2. WORKING DESCRIPTION 

- RCB has 8 operational modes: Chrono, 3 integrated programs, Pilot wire, Comfort, Economy and Antifreeze. 

- To change the current mode, press the FUNCTION button              .

Integrated preset weekly program P1  (work weekly program) at two temperature levels (high and 
low).  All the pilot wire commands, except STOP, are disabled 

Integrated preset weekly program P2 (evening weekly program) at two temperature levels (high 
and low). All the pilot wire commands, except STOP, are disabled 

Integrated preset weekly program P3 (daytime weekly program) at two temperature levels (high 
and low). All the pilot wire commands, except STOP, are disabled

Temperature settings are at two different levels, high and low.  High temperature is used by the Chrono, P1,
P2, P3, Pilot wire and Comfort modes. Low temperature is used by the Chrono, P1, P2, P3 and Economy 
modes. 

The high temperature can be modified only in the Comfort mode and the low one only in the Economy 
mode using  the + and - buttons. 

The thermometer symbol flashes when modification is taking place. During the setting modification, the 
high temperature could be decreased until the current low temperature value (the one shown in the 
Economy mode) and viceversa the low temperature could be increased up to the current  high temperature 
value (the one shown in the Comfort mode). 

IMPORTANT

: Changes in ambient temperature are normal with electronic thermostats when there are 

variations in the power required or when conditions outside the room change. The setting is appropriate 
only for radiators installed in standard environments. It is normal for the regulator setting to be different 
to achieve the same temperature in two separate places (effect of the surrounding environment). 

Содержание RCB

Страница 1: ...Instructions and instalation manual RCB RCBV2_2016_MOOR ESPFUK2016 www haverland co uk CLASS II IP 24 ...

Страница 2: ...ual in order to ensure correct operation TABLE OF CONTENTS 0 General warnings Page 3 0 0 Safety warnings Page 3 1 Heater description Page 3 1 1 Keyboard and LCD display Page 3 1 2 Working description Page 4 1 3 Children s safety Page 5 1 4 Time setting and hourly programming Page 5 1 5 Programmation Function Chrono Page 5 1 6 Integrated programming modes Page 6 1 7 Pilote wire mode Page 7 2 Instru...

Страница 3: ...h external programming devices or any other device of exterior control EXCEPT Pilot Wire external devices The smoke from cigarettes candles and incense burners combined with the effect of convection can cause stains on the wall This is not a failure the apparatus Furthermore the effect of sunlight or halogen may cause some discolouration in the apparatus Temperature variations in the immediate envir...

Страница 4: ...re disabled Integrated preset weekly program P2 evening weekly program at two temperature levels high and low All the pilot wire commands except STOP are disabled Integrated preset weekly program P3 daytime weekly program at two temperature levels high and low All the pilot wire commands except STOP are disabled Temperature settings are at two different levels high and low High temperature is used ...

Страница 5: ...mperature Low temperature 1 4 TIME SETTING AND HOURLY PROGRAMMING 1 Hold down the ON standby and function buttons simultaneously for at least 3 seconds 2 The hour digits begin to flash Use and to set the current hour and confirm by pressing the function button 3 Set the minutes and day in the same way The day is marked by a dot on the vertical numbered scale 1 Monday CONTINUE 1 5 Programmation Funct...

Страница 6: ...n the mode selected in that case following the procedure described at the beginning of the paragraph it is possible to set the time Until the operation is not performed RCB temporarily counts the time from the moment when the power supply 230Vac has become available again and this temporary time is used in case you selected one of the chrono mode RCB has the possibility to use the classic CHRONO M...

Страница 7: ...ket The heater must never be installed in a bathroom in a position in which the switches or other controls can be touched by a person in the bath or shower The RCB heater operates by natural air convection In order to achieve correct performance with uniform heat distribution when installed on a wall the lower part of the heater must a minimum of 10 cm and a maximum of 30 cm from the floor There mu...

Страница 8: ...cted to the mains power supply Only you can to install the radiator in ZONE 3 DO NOT USE THIS HEATER IN THE IMMEDIATE OF A BATH A SHOWER OR A SWIMMING POOL zone 0 1 and zone 2 Marsan Industrial S A reserves the right to modify without previous warning RCB2_2016_MOOR ESPFRUK2016 We recommend that all parts of the radiator are kept clean behind underneath upper fins etc Dust it with a dry and soft cl...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ... Challenge House Sherwood Drive Bletchley MK3 6DP Customer Service Telephone 0330 3651940 Fax 01672 811944 Email haverland haverland co uk www haverland co uk RCB Made in Spain RC12B W 1200 12 Nº 230 V 50 Hz CLASS II IP24 ...

Отзывы: