Operating and maintenance instructions - H14TX - HA16TPX
42
Caution!
4.4 -
STANDBY OPERATION WITH THE STANDBY ELECTROPUMP UNIT
Use of the emergency unit is
exclusively reserved for rescuing
personnel if the main hydraulic
power supply fails. Any other use
may cause damage.
Photo 10:Standby control operation
It is possible to make movements when the main source of power is not
operating correctly. There is an electropump unit supplied by the ignition
battery. This battery can be controlled from both the turntable and the
platform control panels.
The standby electropump control operates on both control panels in the
same way.
• Instructions:
- Select the control panel that you want to validate (orange or green)
(ref 1, Photo: Standby control operation, page 42)
- Activate and hold the standby control switch (ref 2, Photo: Standby
control operation, page 42))
- Activate and hold the switch corresponding to the required
movements (Ref 3, Photo: Standby control operation, page 42).
4.5 -
EMERGENCY OPERATION
If the machine is operating normally but the operator in the platform is
unable to lower the platform, the operator on the ground can do so:
• Switch the selection key to the "platform" position (ref. 14, Photo:
"Turntable" control panel, page 35).
• Control the movements required using the controls corresponding to
normal operation.
1
2
3
Содержание H14T
Страница 1: ...OPERATING AND MAINTENANCE INSTRUCTIONS SELF PROPELLED LIFT H14T X H16TP X 242 032 1790 E 01 07 GB...
Страница 2: ......
Страница 4: ......
Страница 6: ...Operation and maintenance ii...
Страница 20: ...Operation and maintenance 8...
Страница 33: ...Operating and maintenance instructions H14TX HA16TPX 19 2 6 3 Common yellow labels a 19 17 42 41 20...
Страница 38: ...Operating and maintenance instructions H14TX HA16TPX 24...
Страница 46: ...Operating and maintenance instructions H14TX HA16TPX 32...
Страница 58: ...Operating and maintenance instructions H14TX HA16TPX 44...
Страница 67: ...Operating and maintenance instructions H14TX HA16TPX 53...