Grounding Concepts to Avoid Ground Loops
Ground loops are among the most frequent problems in measurement setups with sensitive
sensor technology. They arise through unwanted potential differences inside the current circuit
between sensor and evaluation unit. As a countermeasure we recommend our
Standard
Grounding Concept
or, depending on your application, our
Alternative Grounding Concept
.
Alternative Grounding Concept
In the Alternative Grounding Concept the shield of the sensor cable is connected to the
sensor housing (dotted circle). The sensor housing is uncoupled from the machine ground via
an EMC adapter (black).
Machine
Evaluation Unit
+24V / 4...20mA
Sensor Cable
Machine
+24V / 4...20mA
Sensor Cable
Evaluation
e.g. Ammeter,
PLC
Unit:
Standard Grounding Concept
In the Standard Grounding Concept the shield of the sensor cable is not connected to the sensor
housing (dotted circle). The potential applied to the sensor housing and the machine ground is
identical.
Maschine Ground
Maschine Ground
Sensor
Housing
EMC Adapter
Please indicate in your order if you wish to use the
Alternative Grounding Concept
.
We will then offer you the respective sensor cable and EMC adapter.
Evaluation Unit
Evaluation
e.g. Ammeter,
PLC
Unit:
Shield
Shield
Sensor
Housing