Operation and use
2-4L41C, 2-4M41(Z), 4L42C, 4M42
50
HATZ
Manual
NOTICE
i
The starter protection module prevents the starter from engag-
ing while the engine is running and becoming damaged.
▪
The starter protection module is required when the user
cannot detect at the ignition lock if the engine is still running
or is already at a standstill.
▪
In models equipped with a starter protection module, the
starting key must be kept in the 0 position for at least 8 sec-
onds before another start is possible after the engine is
switched off.
Step
Activity
1
Check the speed adjustment (see chapter
).
2
Remove the protective cap (1) from the ignition lock.
3
Insert the starting key all the way and turn to position "I".
When the pre glow display (3) lights up, wait until it goes out
then continue with step 4.
4
Turn the starting key to position "II".
5
As soon as the engine is running, release the starting key.
▪ The starting key springs back to position "I" and remains in
this position during operation.
▪ The charge control (7) and oil pressure display (6) go out.
▪ Operating display (8) lights up and signals there is no engine
fault.
NOTICE
i
▪
In case of irregularities, switch off the engine immediately.
▪
Identify the fault and eliminate it.
▪
For details of troubleshooting, see chapter
Automatic electrical shutoff (option)
The identifying feature of the electrical automatic shutoff is brief flashing of
all indicator lamps after the starting key is turned to position "I".