![Hatco THERMO-FINISHER TFWM Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/hatco/thermo-finisher-tfwm-series/thermo-finisher-tfwm-series_installation-and-operating-manual_2106695011.webp)
Form No. TFWMM-0817
11
English
OPERATION
Food Finisher Operation
The quick heating, infrared ribbon heating element(s) in each
heating bay are activated by the placement of a plate or tray
on the adjustable shelf. The weight of the plate/tray causes
the adjustable shelf to swing down and back slightly, which
activates a switch. The plate/tray must weigh approximately 1
lb. (0.5 kg) to activate the heating element. The switch signals
the ribbon heating element(s) to begin heating. Removing the
plate/tray from the adjustable shelf deactivates the switch and
signals the ribbon heating elements to return to stand-by mode.
• When a plate/tray is placed on an adjustable shelf, the
POWER ON indicator light for the corresponding heating
bay will illuminate (heating mode). When the plate/tray is
removed, the indicator light will shut off (stand-by mode).
• The bay dividers in between each heating bay are
removable to allow the use of a larger tray across two
adjustable shelves (make sure shelves are at the same
height).
WARNING
BURN HAZARD: Turn power switch OFF (O), unplug power
cord/turn off power at circuit breaker, and allow unit to
cool before performing any maintenance, cleaning, or
adjustments.
• The TOP HEAT CONTROL knobs and BOTTOM HEAT
CONTROL knobs (TFWM42-3939 and TFWM36-3939
only) provide a wide range of adjustment to the heat
intensity of the ribbon heating elements. Test different food
products in the unit to determine the best settings for each.
Weight of plate on adjustable
shelf activates ribbon heating
elements.
Adjustable
Shelf
Removable
Divider
Operating the Food Finisher
Shutdown
1. Wait for fifteen minutes after the last operation of the food
finisher.
2. Move the POWER ON/OFF (I/O) switch to the OFF (O)
position.
• All power to the unit is off and automatic plate/tray
activation is disabled.
• The cooling fans on 3600 and 3636 models will continue
running until unit is cooled.
POWER ON/OFF
(I/O) Switch
BOTTOM HEAT
CONTROL Knob
TOP HEAT
CONTROL Knob
POWER ON
Indicator Light
Left Heating
Bay Controls
Center Heating
Bay Controls
Right Heating
Bay Controls
High Limit
Indicator
Light
Control Panel (TFWM36-3939 shown)