English
Form No. GR5ALM-0217
8
Heat Pattern Dimension
(approximately 12″ [305 mm]—
determined by mounting height)
11–13″
(279–330 mm)
Combustible
10–13″
(254–330 mm)
Non-Combustible
Recommended
Standard Wattage
Height
Recommended
High Wattage
Height
13–16″
(330–406 mm)
Recommended Element Height for the GR5A Series in all widths
NOTE: The size of heat pattern will vary depending on the
height of the unit.
Installing the Unit
Use the following procedure to install the unit using the supplied
angle brackets.
NOTE: Units can be ordered with up to 10ʹ (3 m) of element
wire leads, depending on the installation location of the
control box. On light-equipped units, the LED wire leads
always will be 18" (457 mm) longer than the element
wire leads.
NOTICE
Damage to any countertop material caused by heat
generated from Hatco equipment is not covered under
the Hatco warranty. Contact manufacturer of countertop
material for application information.
1. Determine the exact mounting location on the underside of
the shelf.
NOTE: The attached angle brackets provide 1″ (25 mm)
clearance between the unit and an overshelf.
NOTE: Units can be mounted to a flat shelf or a shelf with
rolled/flanged edges. The unit must be installed with
the minimum 1″ (25 mm) clearance measured from the
lowest part of the overshelf. For example, a shelf with
a 1" (25 mm) flanged edge would require the unit to be
installed 2" (51 mm) below the underside of the shelf. If
minimum distances are not maintained, damage to the
surroundings and/or failure to the unit could occur.
2. Fasten the angle brackets to the underside of the shelf
using appropriate fasteners (not supplied by Hatco). Make
sure the unit is facing the desired direction with the wire
leads on the proper side before fastening the unit to the
shelf.
INSTALLATION
Installation Site Requirements
The installation site must meet specific requirements for safe
and proper installation of the unit.
• Make sure the countertop material is designed to withstand
long periods of hot food holding temperatures. Contact the
manufacturer of the countertop material for application
information.
• Make sure the installation site provides the proper minimum
clearances for adjacent surfaces.
WARNING
FIRE HAZARD: Do not install high wattage units above or
around combustible surfaces. Discoloration or combustion
could occur. High wattage units must be installed in non-
combustible surroundings only.
Minimum Clearance Requirements—
Combustible Surroundings
Model
A
B
C
GR5A and
GR5AL
11ʺ
(279 mm)
1"
(25 mm)
1”
(25 mm)
Minimum Clearance Requirements—
Non-Combustible Surroundings
Model
A
B
C
GR5A and
GR5AL
10ʺ
(254 mm)
0”
(0 mm)
1”
(25 mm)
GR5AH and
GR5AHL
10ʺ
(254 mm)
0”
(0 mm)
1”
(25 mm)
C
B
Shelf
Back or Side W
all
Countertop
A
Minimum Clearances
NOTE: GR5A and GR5AL Series strip heaters can be installed
over a steam table. Follow the minimum clearance
requirements for non-combustible surroundings.
Содержание Glo-Ray GR5A