Symptom
Probable Cause
Corrective Action
Light bulb not working.
Light bulb defective.
Replace light bulb.
Power turned off.
Move I/O (on/off) switch to the
I
(on) position.
Heat is inadequate.
Infinite control set too low.
Adjust infinite control to a higher setting.
Heating element not working.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Infinite control not working properly.
Excessive air movement around unit.
Restrict or redirect air movement (i.e., air conditioning duct or
exhaust fan) away from unit.
Unit connected to incorrect power supply. Contact an Authorized Hatco Service Agent or Hatco for assistance.
Heat is excessive.
Infinite control set too high.
Adjust infinite control to a lower setting.
Infinite control not working properly.
Contact an Authorized Hatco Service Agent or Hatco for assistance.
Unit connected to incorrect power supply.
No heat and no light.
Power turned off.
Move I/O (on/off) switch to the
I
(on) position.
Circuit breaker tripped.
Reset circuit breaker. If circuit breaker continues to trip, contact
Authorized Service Agent or Hatco for assistance.
Control switches burn out.
Remote control enclosure is mounted too
close to the heat zone.
Move remote control enclosure away from the heat zone.
Switches used are not Hatco supplied.
Genuine Hatco Parts are specified to operate safely and properly
in the environment in which they are used. Contact Authorized
Service Agent or Hatco to replace switches with Genuine Hatco
Replacement Parts.
TROUBLESHOOTING GUIDE
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
WARNING
ELECTRIC SHOCK HAZARD: Turn OFF power switch, turn
off power at circuit breaker, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at
www.hatcocorp.com,
select the
Support
pull-
down menu, and click on “Find A Service Agent”; or contact the
Hatco Parts and Service Team
at:
Telephone: 800-558-0607 or 414-671-6350
e-mail: [email protected]
Содержание Glo-Ray Designer GR2A Series
Страница 45: ...Form No GR2AM 0920 45 English NOTES...
Страница 46: ...English Form No GR2AM 0920 46 NOTES...
Страница 47: ...Form No GR2AM 0920 47 English NOTES...