![Hatco FLAV-R-SAVOR FSHC-6W1 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/hatco/flav-r-savor-fshc-6w1/flav-r-savor-fshc-6w1_installation-and-operating-manual_2106629016.webp)
Form No. FSHC67M-0808
14
TROUBLESHOOTING
SYMPTOM
CORRECTIVE ACTION
Unit is plugged in, but does
not power on.
Unit operates correctly, but
does not display cabinet
temperature.
Unit operates, but is not
circulating air inside cabinet.
Unit is not producing any “hot
air” inside cabinet.
Unit is producing very erratic
air
temperatures
inside
cabinet.
Unit is heating, but is not
producing humidity inside
cabinet. Low water light is
OFF, but unit is full of water.
Unit is heating, but is not
producing humidity inside
cabinet. Low water light is
ON, but unit is full of water.
Unit not turned on.
Power On/Off switch defective.
Electrical receptacle is defective.
Tripped circuit breaker.
Internal electrical defect.
Temperature indicating device is
defective.
Blower motor is defective.
Air heating element or blower motor
is defective.
Air thermostat control is defective.
Air down tube is not connected.
Humidity thermostat control is set
too low.
Humidity thermostat control system
is defective.
Float switch inside water reservoir is
limed up or dirty.
Low water control system is
defective.
Water heating element is defective.
PROBABLE CAUSE
Move Power On/Off switch to the on
position.
Contact Authorized Service Agent or
Hatco for assistance.
Check outlet and verify power
supply matches specification tag on
unit.
Check circuit breaker and reset if
tripped.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Clean/Delime water reservoir per
instructions in Operations Manual.
Adjust humidity control to higher
setting.
Reconnect air down tube.
WARNING
This unit must be serviced by qualified
personnel only. Service by unqualified
personnel may lead to electric shock or burn.
WARNING
ELECTRIC SHOCK HAZARD: Turn the power
switch OFF, unplug the power cord, and allow
the unit to cool before performing any
maintenance or cleaning.
Содержание FLAV-R-SAVOR FSHC-6W1
Страница 18: ...Form No FSHC67M 0808 16 NOTES ...